Radiofrequency endocardial catheter ablation of accessory atrioventricular pathway atrial insertion sites.

Author:

Swartz J F1,Tracy C M1,Fletcher R D1

Affiliation:

1. Department of Medicine, Uniformed Services University of the Health Sciences, Bethesda, Md 20814-4799.

Abstract

BACKGROUNDHigh rates of success using radiofrequency ablation energy have rapidly transformed catheter ablation from an investigational procedure to the nonpharmacological therapy of choice for symptomatic Wolff-Parkinson-White syndrome. Prior studies of radiofrequency accessory pathway ablation were based on a ventricular approach. Risks associated with prolonged arterial catheter manipulation, retrograde left ventricular catheterization, and production of ventricular lesions required for successful ventricular insertion ablation can be avoided using atrial insertion ablation procedures. The purpose of the present study was to define the safety and efficacy of accessory pathway ablation using radiofrequency energy delivered solely to accessory atrioventricular pathway atrial insertion sites.METHODS AND RESULTSOne hundred fourteen patients with accessory pathway-mediated tachycardia underwent attempted radiofrequency current ablation at the accessory pathway atrial insertion site. All catheters were introduced transvenously. Left-sided accessory pathways were approached using transseptal left atrial catheterization techniques. Retrograde localization of the atrial insertion site during reentrant tachycardia was characterized by 40 +/- 15-msec local ventriculoatrial and 79 +/- 17-msec surface QRS to local atrial electrogram intervals. Presumed accessory pathway potentials were present in only 30% of ablation site electrograms. Successful ablation required 6.2 +/- 5.3 radiofrequency energy applications. Cumulative energy dose required for success was 2,341 +/- 2,233 J. There were no complications associated with transseptal catheterization. Energy delivery to accessory pathway atrial insertion sites was associated with non-life-threatening complications in two patients. Recurrent conduction requiring repeat ablation occurred in 10 of 115 (9%) successfully ablated accessory pathways, all within 1 month of the ablation procedure. After 21.2 +/- 4.6 months of follow-up, 108 of 114 (95%) patients are asymptomatic and without evidence of accessory pathway conduction.CONCLUSIONSThe atrial insertion approach to accessory pathway ablation is safe and highly effective. This approach compares favorably with the retrograde ventricular insertion ablation technique. Atrial insertion ablation eliminates the need to produce ventricular lesions and avoids the risks of prolonged arterial catheter manipulation and retrograde left ventricular catheterization.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 117 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3