Instantaneous hyperemic flow-versus-pressure slope index. Microsphere validation of an alternative to measures of coronary reserve.

Author:

Mancini G B1,Cleary R M1,DeBoe S F1,Moore N B1,Gallagher K P1

Affiliation:

1. Department of Internal Medicine, University of Michigan Medical School, Ann Arbor.

Abstract

BACKGROUND The instantaneous hyperemic flow-versus-pressure (i-HFVP) slope index is a new method of assessing maximal coronary conductance and can be used as an alternative to conventional measures of coronary reserve. The i-HFVP slope index is determined by measuring the slope of the linear diastolic segment of the relation between instantaneous aortic pressure and hyperemic coronary flow. METHODS AND RESULTS To validate the i-HFVP slope index as a measure of maximal coronary conductance, we compared this method with a microsphere-derived measurement of maximal coronary conductance (m-HFVP slope index) by determining the slope of the least-squares regression line of the data points for coronary flow during maximal hyperemia and four or five steady-state alterations of aortic pressure in 43 dogs (open-chest, anesthetized preparations) with or without coronary stenoses. The i-HFVP slope index demonstrated no dependence on heart rate, left ventricular end-diastolic pressure, or mean aortic pressure and was highly reproducible within the groups studied (intraclass correlation coefficient, 0.86 for normal arteries, 0.87 for stenotic arteries, and 0.93 for combined groups; for all coefficients, p less than 0.001). The i-HFVP slope index was significantly decreased in the presence of a stenosis (10.3 +/- 3.9 for normal arteries versus 3.6 +/- 1.6 for stenotic arteries, p less than 0.001) as was the transmural m-HFVP slope index (8.9 +/- 4.6 for normal arteries versus 5.3 +/- 3.1, p less than 0.01). Of special importance, the i-HFVP slope index measurement for normal arteries was not significantly different from the transmural and subendocardial m-HFVP slope index measurements (10.3 +/- 3.9 versus 8.9 +/- 4.6 and 9.2 +/- 5.7, respectively). For stenotic arteries, the i-HFVP slope index measurement was also not significantly different from the transmural and subendocardial m-HFVP slope index measurements (3.6 +/- 1.6 versus 5.3 +/- 3.1 and 4.1 +/- 2.3, respectively). The i-HFVP slope index correlated best with subendocardial m-HFVP slope index measurements (correlation coefficient, 0.57; p less than 0.001). When the 95% confidence intervals for the transmural (or subendocardial) m-HFVP slope index in normal arteries were compared with the i-HFVP slope index values, the latter demonstrated a systematic trend to overestimate the m-HFVP slope index. In the presence of a stenosis, this effect was minimized, and the slope values were nearly identical. CONCLUSIONS The i-HFVP slope index correlates most closely with subendocardial coronary conductance; the index is a hemodynamically independent measure of coronary reserve that is reproducible over a broad range of aortic pressures; and the methodology is applicable to an intact circulation in experimental preparations and may with future developments also prove useful in humans.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3