Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload.

Author:

McGinn A L1,White C W1,Wilson R F1

Affiliation:

1. Department of Medicine, University of Minnesota, Minneapolis 55455.

Abstract

To define the long-term variability of serial coronary flow reserve (CFR) measurements in humans and to evaluate the influence of changes in heart rate, mean arterial pressure, and left ventricular preload on CFR, 45 patients with normal left ventricular function (38 cardiac allograft recipients, five patients with normal coronary arteries, and two patients with minimal coronary artery disease [less than 50% diameter stenosis]) were studied. CFR (ratio of peak hyperemic [h] to resting [r] coronary blood flow velocity [CBFV]) was measured with a 3F coronary Doppler catheter and intracoronary papaverine. Initial CFR measurements were highly correlated with repeat measurements obtained 11 +/- 0.6 months later (r = 0.95; mean absolute difference, 0.3 +/- 0.1; n = 17). Differences in CFR between studies were related to changes in heart rate (r = 0.61, p = 0.01) but not to changes in mean arterial pressure (r = 0.25, p = 0.33). To define the effects of rapid changes in heart rate, mean arterial pressure, and preload on CFR, these variables were altered by atrial pacing, handgrip exercise, and volume expansion, respectively. Atrial pacing produced a rate-related increase in rCBFV but did not change hCBFV. Consequently, CFR was significantly reduced as heart rate was increased progressively from 76 +/- 2 in sinus rhythm (4.5 +/- 0.2) to 100 (3.8 +/- 0.2, p less than 0.05, n = 32) to 120 beats/min (3.2 +/- 0.1, p less than 0.05, n = 7). Despite a 19 +/- 2 mm Hg rise in mean arterial pressure during handgrip exercise, CFR was unchanged from baseline (3.7 +/- 0.3 vs. 3.7 +/- 0.4, p = NS, n = 7) because rCBFV rose proportionally with hCBFV. When pulmonary capillary wedge pressure was increased from 9 +/- 1 to 16 +/- 1 mm Hg after volume expansion, CFR was significantly decreased (from 3.8 +/- 0.2 to 2.9 +/- 0.2, p less than 0.05, n = 9) because rCBFV was increased while hCBFV remained unchanged. Hence, serial CFR measurements in humans are highly reproducible in the absence of conditions known to affect resting or hyperemic coronary blood flow. Increases in heart rate or preload reduced CFR because rCBFV was increased while hCBFV was unchanged. In contrast, changes in mean arterial pressure did not alter CFR. Proper interpretation of CFR measurements should take into account the hemodynamic conditions at which they are obtained.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 286 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3