Determination of coronary flow reserve by parametric imaging.

Author:

Hess O M1,McGillem M J1,DeBoe S F1,Pinto I M1,Gallagher K P1,Mancini G B1

Affiliation:

1. Department of Internal Medicine, Veterans Administration Medical Center, Ann Arbor, MI 48105.

Abstract

Nine mongrel dogs were instrumented with electromagnetic flow probes (EMF) to measure coronary blood flow through the left anterior descending (LAD) and left circumflex (LCx) coronary arteries at rest and after maximal coronary vasodilation (1 mg/kg/min adenosine). Relative coronary blood flow was determined by parametric imaging in the left posterior oblique projection using digital subtraction angiography (DSA). Transmural myocardial perfusion of the LAD and LCx beds was determined with tracer-labeled microspheres. Coronary flow reserve (maximal coronary blood flow divided by resting blood flow) was calculated under control conditions and after constriction of the proximal LAD or LCx by a screw occluder. Heart rate decreased significantly from 140 beats/min at rest to 122 beats/min after adenosine (p less than 0.001) and from 134 (rest) to 120 beats/min (adenosine; p less than 0.05) after coronary constriction. Peak systolic pressure was kept constant with an aortic constrictor. Left ventricular end-diastolic pressure increased significantly from 18 mm Hg at rest to 23 mm Hg (p less than 0.05) after coronary constriction. At baseline, coronary flow reserve was 4.2 with DSA, 3.8 with EMF, and 3.7 with microspheres; after coronary constriction, it was 2.6 (DSA), 1.9 (EMF), and 1.5 (microspheres) (all p less than 0.001 versus baseline). Coronary blood flow showed a good correlation between EMF and microspheres (r = 0.87, p less than 0.001), with a standard error of estimate (SEE) of 0.78 ml/g/min. Coronary flow reserve also showed a good correlation between EMF and microspheres (r = 0.82, p less than 0.001), with an SEE of 0.93. There was a moderate correlation between EMF and DSA (r = 0.68, p less than 0.001), with an SEE of 1.35 (40% of mean coronary flow reserve). The correlation coefficient between microspheres and DSA was 0.54 (p less than 0.01), with an SEE of 1.46 (39% of mean coronary flow reserve). The mean difference (accuracy) and standard deviation of difference (precision) were 0.2 +/- 1.0 between EMF and microspheres, -0.1 +/- 1.4 between EMF and DSA, and -0.6 +/- 1.7 between microspheres and DSA. We conclude that determination of coronary flow reserve by parametric imaging is associated with large variations that are greater than variations also inherent in the two reference techniques. Parametric imaging allows relatively accurate assessment of coronary flow reserve (small mean difference), but precision is low (large standard deviation of mean differences).(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3