Using temporary atrial wire electrodes placed at selected atrial sites, rapid atrial pacing at rates of up to 368 beats/min was used to study atrial excitability and conduction in seven patients who underwent open heart surgery. The threshold for atrial pacing was found to be an exponential function of pacing rate (r = 0.55, p less than 0.01), increasing threefold when the fastest pacing rates were compared with the slowest pacing rates (p less than 0.005). Atrial conduction times (measured from pacing to recording sites), prolonged during rapid atrial pacing both for studies conducted before institution of cardiopulmonary bypass (p less than 0.005) and for those done 7 days postoperatively (p less than 0.05). However, prolongation of conduction times always depended on achievement of a critically rapid pacing rate. During rapid atrial pacing, we observed a high incidence of alternans of the atrial electrogram (17 of 42 studies). Thus, human atrial excitability, conduction and electrogram morphology are not constant during pacing at rapid rates. Rather, at rapid pacing rates, there is depression of atrial excitability, prolongation of atrial conduction times and alternation in electrogram morphology. These findings have clinical relevance and theoretical implications for the understanding and treatment of rapid atrial rhythms.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference13 articles.

1. Observations upon flutter and fibrillation. PartII. The nature of auricularflutter;Lewis T;Heart,1920

2. Mechanism of the Auricular Arrhythmias

3. Boineau JP Mooney CR Hudson RD Hughes DG Erdin RA Jr Wylds AC: Observations on reentrant excitation pathways and refractory period. Distributions in spontaneous and experimental atrial flutter in the dog. In Reentrant Arrhythmias edited by Kulbertus HE. Baltimore University Park Press

4. Use of temporarily placed epicardial atrial wire electrodes for the diagnosis and treatment of cardiac arrhythmias following open heart surgery;Waldo AL;J Thorac Cardiovasc Surg,1978

5. Problems in measuring threshold for cardiac pacing

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Clinical Electrophysiology Techniques;Electrophysiological Disorders of the Heart;2012

2. Cardiac Electrical Stimulation;Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy;2011

3. Alterations of atrial Ca2+ handling as cause and consequence of atrial fibrillation;Cardiovascular Research;2010-12-15

4. QT Interval, U Wave Abnormalities, and Cardiac Alternans;Chou's Electrocardiography in Clinical Practice;2008

5. Cardiac Electrical Stimulation;Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy;2007