Oral Heparin Prevents Neointimal Hyperplasia After Arterial Injury

Author:

Welt Frederick G.P.1,Woods T. Cooper1,Edelman Elazer R.1

Affiliation:

1. From the Department of Medicine, Cardiac Catheterization Laboratory and Coronary Care Unit, Cardiovascular Division, Brigham and Women’s Hospital, Harvard Medical School, Boston, Mass (F.G.P.W., E.R.E.); the Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Mass (F.G.P.W., E.R.E.); the West Roxbury Veteran’s Affairs Medical Center, West Roxbury, Mass (F.G.P.W.); and Emisphere Technologies Inc, Tarrytown, NY (T.C.W.).

Abstract

Background In animal models, heparin delivered as a continuous intravenous infusion or via frequent (BID) subcutaneous dosing inhibits neointimal hyperplasia after balloon injury or stent implantation. However, human trials of subcutaneous heparin after percutaneous intervention have proven ineffective against restenosis. It may be that these failures are due to unfavorable heparin pharmacokinetics. Recently, the drug delivery agent sodium N -[8-(2-hydroxybenzoyl)amino] caprylate (SNAC) has been found to facilitate the gastric absorption of heparin. Methods and Results To investigate the effects of orally delivered heparin on neointimal hyperplasia after varying forms of arterial injury, 57 New Zealand White rabbits underwent iliac artery balloon dilatation. In half of the rabbits, endovascular stents were implanted and heparin was delivered through a variety of methods. Arteries were harvested at 14 days. Neointimal area was assessed with computer-aided morphometry. After balloon injury, both intravenous (0.3 mg/kg per hour) and oral heparin (90 mg/kg BID) effectively inhibited neointimal hyperplasia (0.11±0.02 and 0.09±0.07 mm 2 , respectively, versus 0.16±0.06 mm 2 in control; P <0.05). After stent implantation, intravenous administration of heparin (0.3 mg/kg per hour) effectively inhibited neointimal growth (0.35±0.05 mm 2 versus 0.51±0.09 mm 2 in control; P <0.05), but oral heparin at 90 mg/kg BID and 180 mg/kg BID (0.48±0.04 and 0.49±0.08 mm 2 , respectively; P =NS versus control) did not. A dose of 120 mg/kg TID, however, was effective (0.40±0.10 mm 2 ; P <0.05 versus control). Conclusions These data suggest that oral heparin may be an effective therapy against restenosis after percutaneous intervention. Stented arteries required higher and more frequent dosing for efficacy. These data suggest that differences in the type of vascular injury must be considered in the design of drug delivery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3