Use of an Inspiratory Impedance Valve Improves Neurologically Intact Survival in a Porcine Model of Ventricular Fibrillation

Author:

Lurie Keith G.1,Zielinski Todd1,McKnite Scott1,Aufderheide Tom1,Voelckel Wolfgang1

Affiliation:

1. From the Cardiac Arrhythmia Center, University of Minnesota, Minneapolis (K.G.L., T.Z., S.M., W.V.); the Department of Emergency Medicine, Medical College of Wisconsin, Milwaukee (T.A.); and the Department of Anesthesiology, Leopold-Franzens-University, Innsbruck, Austria (W.V.).

Abstract

Background This study evaluated the potential for an inspiratory impedance threshold valve (ITV) to improve 24-hour survival and neurological function in a pig model of cardiac arrest. Methods and Results Using a randomized, prospective, and blinded design, we compared the effects of a sham versus active ITV on 24-hour survival and neurological function. After 6 minutes of ventricular fibrillation (VF), followed by 6 minutes of cardiopulmonary resuscitation (CPR) with either a sham or an active valve, anesthetized pigs received 3 sequential 200-J shocks. If VF persisted, they received epinephrine (0.045 mg/kg), 90 seconds of CPR, and 3 more 200-J shocks. A total of 11 of 20 pigs (55%) in the sham versus 17 of 20 (85%) in the active valve group survived for 24 hours ( P <0.05). Neurological scores were significantly higher with the active valve; the cerebral performance score (1=normal, 5=brain death) was 2.2±0.2 with the sham ITV versus 1.4±0.2 with the active valve ( P <0.05). A total of 1 of 11 in the sham versus 12 of 17 in the active valve group had completely normal neurological function ( P <0.05). Peak end-tidal CO 2 (P etco 2 ) values were significantly higher with the active valve (20.4±1.0) than the sham (16.8±1.5) ( P <0.05). P etco 2 >18 mm Hg correlated with increased survival ( P <0.05). Conclusions Use of a functional ITV during standard CPR significantly improved 24-hour survival rates and neurological recovery. P etco 2 and systolic blood pressure were also significantly higher in the active valve group. These data support further evaluation of ITV during standard CPR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 122 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3