Aortic Valve Annular Sizing

Author:

George Isaac1,Guglielmetti Laura C.1,Bettinger Nicolas1,Moss Andrew1,Wang Catherine1,Kheysin Nathan1,Hahn Rebecca1,Kodali Susheel1,Leon Martin1,Bapat Vinayak1,Borger Michael A.1,Williams Mathew1,Smith Craig1,Khalique Omar K.1

Affiliation:

1. From the Division of Cardiothoracic Surgery, New York Presbyterian Hospital – College of Physicians and Surgeons of Columbia University, New York, NY (I.G., A.M., C.W., N.K., C.S.); Division of Thoracic Surgery, University Hospital of Zurich, Switzerland (L.C.G.); Division of Cardiology, New York Presbyterian Hospital – College of Physicians and Surgeons of Columbia University, NY (N.B., R.H., S.K., M.L., M.A.B., O.K.K.); Division of Cardiothoracic Surgery, Guys and St. Thomas Hospital Trust, London...

Abstract

Background— Appropriate valve sizing is critical in aortic valve replacement. We hypothesized that direct intraoperative valve sizing results in smaller aortic annular diameters compared with sizing based on systolic-phase multidetector computerized tomographic (MDCT) imaging. Methods and Results— We retrospectively analyzed 78 patients undergoing surgical aortic valve replacement for severe aortic stenosis between 2012 and 2014 at our institution. Preoperative MDCT measurements of the aortic annulus served as basis for assignment to a theoretical surgical valve size, which was then (1) compared to the implanted valve size and (2) to a theoretical transcatheter aortic valve replacement valve size. To quantify the resulting differences, geometric orifice areas (GOA) were calculated. MDCT-based sizing produced the same valve size for n=34 patients (group CT-same), a larger valve with a 25% increased GOA in n=32 patients (group CT-Lg) and a smaller GOA by 22% in n=12 patients (group CT-Sm). On the basis of MDCT measurements, 41% of valves implanted were undersized. The comparison of intraoperative implanted to a theoretical transcatheter aortic valve replacement valve size resulted in GOAs 25% larger for patients in group CT-same, 40.6% larger in group CT-Lg and 14.6% larger in group CT-Sm. Conclusions— Preoperative MDCT measurements differ substantially from direct intraoperative assessment of the aortic annulus. Implanted surgical aortic valve replacement valves were smaller relative to MDCT-based sizing in 41% of patients, and the potential GOA was between 25% and 40.6% larger if patients had undergone transcatheter aortic valve replacement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3