Association Between Left Atrial Dilatation and Invasive Hemodynamics at Rest and During Exercise in Asymptomatic Aortic Stenosis

Author:

Christensen Nicolaj Lyhne1,Dahl Jordi Sanchez1,Carter-Storch Rasmus1,Bakkestrøm Rine1,Jensen Kurt1,Steffensen Flemming Hald1,Søndergaard Eva Vad1,Videbæk Lars1,Møller Jacob Eifer1

Affiliation:

1. From the Department of Cardiology, Odense University Hospital, Denmark (N.L.C., J.S.D., R.C.-S., R.B., E.V.S., L.V., J.E.M.); Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense (K.J.), and Department of Cardiology, Lillebaelt Hospital, Vejle, Denmark (F.H.S.).

Abstract

Background— Transition from an asymptomatic to symptomatic state in severe aortic stenosis is often difficult to assess. Identification of a morphological sign of increased hemodynamic load may be important in asymptomatic aortic stenosis to identify patients at risk. Methods and Results— Thirty-nine patients with asymptomatic severe aortic stenosis (aortic valve area <1 cm 2 , peak jet velocity >3.5 m/s) underwent exercise testing with simultaneous invasive hemodynamic monitoring and Doppler echocardiography. Cardiac index, pulmonary artery pressure, and pulmonary capillary wedge pressure (PCWP) were recorded. Patients were followed up for the composite end point of death, unplanned hospitalization, or aortic valve replacement. Patients were stratified into 2 groups according to left atrial (LA) volume index ≥35 mL/m 2 . In 25 patients (64%) LA volume index was ≥35 mL/m 2 . Aortic valve area was similar between groups (0.81±0.15 versus 0.84±0.18 cm 2 ; P =0.58). PCWP was higher at rest and during exercise in patients with LA volume index ≥35 mL/m 2 ( P <0.01), despite similar cardiac index. At rest, PCWP was <12 mm Hg in 11 patients (44%) with LA dilatation, whereas PCWP was <25 mm Hg in 1 patient (4%) with exercise. LA volume index and E/e′ predicted exercise PCWP>30 mm Hg with areas under the receiver operating curve of 0.75 and 0.84, respectively. During follow-up, 14 cardiac events were recorded. LA volume was associated with a hazard ratio of 1.90 (95% confidence interval, 0.92–4.15). Conclusions— LA size reflects hemodynamic burden in patients with asymptomatic severe aortic stenosis. Quantitative measurements of LA and diastolic function are associated with left ventricular filling pressures with exercise and could be used to identify asymptomatic patients with increased hemodynamic burden. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT02395107.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3