Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection

Author:

Juneau Daniel1,Golfam Mohammad1,Hazra Samir1,Zuckier Lionel S.1,Garas Shady1,Redpath Calum1,Bernick Jordan1,Leung Eugene1,Chih Sharon1,Wells George1,Beanlands Rob S.B.1,Chow Benjamin J.W.1

Affiliation:

1. From the Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, Ontario, Canada (D.J., S.H., C.R., J.B., S.C., G.W., R.S.B.B., B.J.W.C.); Division of Nuclear Medicine, Department of Medicine, University of Ottawa, Ontario, Canada (M.G., L.S.Z., S.G., E.L.); and Division of Nuclear Medicine, Medical Imaging Department, Centre Hospitalier de l’Université de Montréal (CHUM), Montréal, Québec, Canada (D.J.).

Abstract

Background— The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography , labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy for the diagnosis of CIED infection. Methods and Results— A systematic review of the literature and meta-analysis on the use of all 3 modalities in CIED infection were conducted. Pooled sensitivity, specificity, and summary receiver operating characteristic curves of each imaging modalities were determined. The literature search identified 2493 articles. A total of 13 articles (11 studies for 18 F-FDG PET-CT and 2 for LS), met the inclusion criteria. No studies for 67 Ga citrate scintigraphy met the inclusion criteria. The pooled sensitivity of 18 F-FDG PET-CT for the diagnosis of CIED infection was 87% (95% CI, 82%–91%) and pooled specificity was 94% (95% CI, 88%–98%). The summary receiver operating characteristic curve analysis demonstrated good overall accuracy, with an area under the curve of 0.935. There were insufficient data to do a meta-analysis for LS, but both studies reported sensitivity above 90% and specificity of 100%. Conclusions— Both 18 F-FDG PET-CT and LS yield high sensitivity, specificity, and accuracy, and thus seem to be useful for the diagnosis of CIED infection, based on robust data for 18 F-FDG PET-CT but limited data for LS. When available, 18 F-FDG PET-CT may be preferred.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 130 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3