Progressive Radiation Dose Reduction From Coronary Computed Tomography Angiography in a Statewide Collaborative Quality Improvement Program

Author:

Chinnaiyan Kavitha M.1,Boura Judith A.1,DePetris Ann1,Gentry Ralph1,Abidov Aiden1,Share David A.1,Raff Gilbert L.1

Affiliation:

1. From the Cardiology Division, William Beaumont Hospital, Royal Oak, MI (K.M.C., J.A.B., A.D., R.G., G.L.R.); Sarver Heart Center, College of Medicine, University of Arizona, Tucson, AZ (A.A.); and Department of Family Medicine, University of Michigan Health System, Ann Arbor, MI (D.A.S.).

Abstract

Background— A best-practice intervention previously demonstrated significant dose reduction over a period of one year. We sought to evaluate whether this reduction would be incremental and sustained by promoting new scanner technology in the context of an ongoing quality improvement program during a 3-year period in a statewide registry of coronary computed tomography angiography. Methods and Results— In this prospective, controlled, nonrandomized study involving 11 901 patients at 15 Michigan centers participating in the Advanced Cardiovascular Imaging Consortium, radiation doses and image quality were compared between the following periods: control (May to June 2008) versus follow-up I (July 2008 to June 2009) and follow-up I versus follow-up II (July 2009 to April 2011). Intervention during these study periods included continuous education, feedback, and mandatory participation in this initiative. The median radiation dose remained unchanged from control to follow-up I: dose-length product of 697 (interquartile range, 407–1163) to 675 (interquartile range, 418–1146) mGy·cm ( P =0.93). With the introduction of newer technology in follow-up I period, there was incremental 31% decrease during follow-up II to median dose-length product of 468 (interquartile range, 292–811) mGy·cm ( P <0.0001). No significant change was noted in the percentage of diagnostic quality scans from follow-up I (92%) to follow-up II (92.7%). Conclusions— Although ongoing application of a best-practice algorithm was associated with sustaining previously achieved targets, the use of newer scanner technology resulted in incremental radiation dose reduction in a statewide coronary computed tomography angiography registry without image quality degradation. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00640068.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司