Three-Dimensional Echocardiography Compared With Computed Tomography to Determine Mitral Annulus Size Before Transcatheter Mitral Valve Implantation

Author:

Mak George J.1,Blanke Philipp1,Ong Kevin1,Naoum Christopher1,Thompson Christopher R.1,Webb John G.1,Moss Robert1,Boone Robert1,Ye Jian1,Cheung Anson1,Munt Brad1,Leipsic Jonathon1,Grewal Jasmine1

Affiliation:

1. From the St Paul’s Hospital, University of British Columbia, Vancouver, Canada.

Abstract

Background— Previously, through the use of computed tomography (CT), it has been proposed that D-shaped versus saddle-shaped mitral annulus (MA) segmentation is more biomechanically appropriate to determine transcatheter mitral valve implantation size and eligibility. Methods and Results— Forty-one patients with severe mitral regurgitation being considered for transcatheter mitral valve implantation who had undergone cardiac CT and 3-dimensional transesophageal echocardiography (3D-TEE) were retrospectively evaluated. A standardized segmentation protocol for the D-shaped MA was developed using Philips Q-Laboratory mitral valve quantification software. MA dimensions were compared using Spearman’s rank correlation and Bland–Altman analysis. Inter- and intraobserver agreement was quantified by intraclass correlation coefficient and Bland–Altman analysis. Mean age was 77±14 years; 71% male (n=29); mitral regurgitation pathogenesis was functional in 54% (n=22) and myxomatous in 46% (n=19). Mean MA area and circumference by 3D-TEE and CT were 11.3±2.7 versus 11.4±3.0 ( P =0.67) and 124.1±15.6 versus 123.9±15.5 ( P =0.79), respectively, with excellent correlation between modalities ( r =0.84 and r =0.86; P <0.0001) and no systematic bias (−0.20±1.8 cm 2 [−3.7 cm 2 ; 3.3 cm 2 ], 0.37±9 mm [−18.0 mm; 17.27 mm]). Mean septal-to-lateral and inter-trigone distances by 3D-TEE and CT were 33.2±4.7 versus 32.5±4.4 ( P =0.24) and 31.7±3.5 versus 32.6±3.6 ( P =0.06), respectively, with good correlation ( r =0.69 and r =0.71; P <0.0001) and no systematic bias (0.77±3.8 mm [−6.7 mm; 8.2 mm], −1.5±3.1 mm [−4.6 mm; 7.6 mm]). There was excellent intra- and interobserver agreement according to intraclass correlation coefficients >0.90 for all parameters. Conclusions— Similar to cardiac CT, 3D-TEE allows for D-shaped MA segmentation with no systematic difference in MA dimensions between modalities. This study supports the utilization of 3D-TEE as a complementary tool to CT assessment of the D-shaped MA to determine transcatheter mitral valve implantation size.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3