Test-Retest Precision of Myocardial Blood Flow Measurements With 99m Tc-Tetrofosmin and Solid-State Detector Single Photon Emission Computed Tomography

Author:

Wells R. Glenn1,Radonjic Ivana1,Clackdoyle Duncan1,Do Jeffrey1,Marvin Brian1,Carey Clare1,deKemp Robert A.1,Ruddy Terrence D.1

Affiliation:

1. Division of Cardiology, University of Ottawa Heart Institute, Ottawa, ON, Canada.

Abstract

Background: Measurement of myocardial blood flow (MBF) with single photon emission computed tomography (SPECT) is feasible using cardiac cameras with solid-state detectors. SPECT MBF has been shown to be accurate when compared with positron emission tomography MBF measured in the same patients. However, the value of a test result applied to an individual patient depends strongly on the precision or repeatability of the test. The purpose of our study is to measure the precision of SPECT MBF measurements using 99m Tc-tetrofosmin and a solid-state cardiac camera. Methods: SPECT MBF was measured in 30 patients and repeated at a mean interval of 18 days. MBF was evaluated from images with and without attenuation correction based on a separately acquired CT scan. The dynamic images were processed independently by 2 operators using in-house kinetic analysis software that applied a 1-tissue-compartment model. The K1 rate constant was converted to MBF using previously determined extraction fraction corrections. Correction for patient body motion was applied manually. Results: The average coefficient of variation (COV) in the differences between the 2 MBF measurements was between 28% and 31%. The interobserver COV was between 11% and 15%. Myocardial flow reserve is the ratio of MBF measured at stress and rest, and the COV is correspondingly higher. The COV for the difference in repeated myocardial flow reserve was 33% to 38%, whereas the interobserver COV was 13% to 22%. Conclusions: The COV for the difference in SPECT MBF measurements obtained on separate days is 28% to 31%. The corresponding COV for myocardial flow reserve is 33% to 38%.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3