Clinical Value of Absolute Quantification of Myocardial Perfusion With 15 O-Water in Coronary Artery Disease

Author:

Kajander Sami A.1,Joutsiniemi Esa1,Saraste Markku1,Pietilä Mikko1,Ukkonen Heikki1,Saraste Antti1,Sipilä Hannu T.1,Teräs Mika1,Mäki Maija1,Airaksinen Juhani1,Hartiala Jaakko1,Knuuti Juhani1

Affiliation:

1. From the Turku PET Centre (S.K., H.T.S., M.T., J.K.), Department of Medicine (E.J., M.P., H.U., A.S., J.A.), and Department of Clinical Physiology and Nuclear Medicine (M.S., M.M., J.H.), University of Turku, Turku, Finland.

Abstract

Background— The standard interpretation of perfusion imaging is based on the assessment of relative perfusion distribution. The limitations of that approach have been recognized in patients with multivessel disease and endothelial dysfunction. To date, however, no large clinical studies have investigated the value of measuring quantitative blood flow and compared that with relative uptake. Methods and Results— One hundred four patients with moderate (30%–70%) pretest likelihood of coronary artery disease (CAD) underwent PET imaging during adenosine stress using 15 O-water and dynamic imaging. Absolute myocardial blood flow was calculated from which both standard relative myocardial perfusion images and images scaled to a known absolute scale were produced. The patients and the regions then were classified as normal or abnormal and compared against the reference of conventional angiography with fractional flow reserve. In patient-based analysis, the positive predictive value, negative predictive value, and accuracy of absolute perfusion in the detection of any obstructive CAD were 86%, 97%, and 92%, respectively, with absolute quantification. The corresponding values with relative analysis were 61%, 83%, and 73%, respectively. In region-based analysis, the receiver operating characteristic curves confirmed that the absolute quantification was superior to relative assessment. In particular, the specificity and positive predictive value were low using just relative differences in flow. Only 9 of 24 patients with 3-vessel disease were correctly assessed using relative analysis. Conclusions— The measurement of myocardial blood flow in absolute terms has a significant impact on the interpretation of myocardial perfusion. As expected, multivessel disease is more accurately detected. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00627172.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司