Aortic Root Measurement by Cardiovascular Magnetic Resonance

Author:

Burman Elisabeth D.1,Keegan Jennifer1,Kilner Philip J.1

Affiliation:

1. From the Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, United Kingdom.

Abstract

Background— Cardiovascular magnetic resonance is widely used for aortic root visualization and measurement, but methods still need to be standardized. Our aim was to identify appropriate planes of acquisition and lines of measurement and record corresponding normal values. Methods and Results— We studied 120 healthy volunteers, 10 of each gender in each decile between 20 and 80 years, by using a 1.5-T cardiovascular magnetic resonance system. Steady-state free precession cine acquisitions aligned with the left ventricular outflow tract in oblique sagittal and coronal orientations were used to locate 2 sinus planes that transected the root at its widest point in its maximally expanded systolic and at its end diastolic positions. We measured the cusp-cusp and the cusp-commissure dimensions in these cine planes, each as the average of 3. Diastolic cusp-commissure dimensions were smaller than diastolic cusp-cusp dimensions (32.0�3.5 mm versus 34.6�4.0 mm in men, 28.4�2.8 mm versus 30.7�3.3 mm in women, P <0.001 for both). The diastolic cusp-commissure dimensions increased by 0.9 mm per decade in men and 0.7 mm per decade in women ( P <0.001 for both) and gave higher R 2 values with respect to age and body surface area (0.40 for men, 0.27 for women) than diastolic cusp-cusp, systolic cusp-commissure, or sinus measurements made in the left ventricular outflow tract planes. Conclusions— The results indicate the importance of consistent methods for measurement of the aortic root by cardiovascular magnetic resonance. We recommend diastolic cusp-commissure measurements, which yielded favorable R 2 values with respect to age and body surface area and were found to correspond closely with reference echocardiographic root measurements recorded in the Framingham cohort. We recorded reference values for these and other possible aortic root measurements by cardiovascular magnetic resonance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3