A Study of Functional Anatomy of Aortic-Mitral Valve Coupling Using 3D Matrix Transesophageal Echocardiography

Author:

Veronesi Federico1,Corsi Cristiana1,Sugeng Lissa1,Mor-Avi Victor1,Caiani Enrico G.1,Weinert Lynn1,Lamberti Claudio1,Lang Roberto M.1

Affiliation:

1. From the Department of Electronics, Computer Science and Systems (F.V., C.C., C.L.), University of Bologna, Italy; Department of Medicine, Section of Cardiology, University of Chicago Medical Center (L.S., V.M.-A., L.W., R.M.L.), Ill; and the Department of Biomedical Engineering (F.V., E.G.C.), Politecnico di Milano, Milan, Italy.

Abstract

Background— Mitral and aortic valves are known to be coupled via fibrous tissue connecting the two annuli. Previous studies evaluating this coupling have been limited to experimental animals using invasive techniques. The new matrix array transesophageal transducer provides high-resolution real-time 3D images of both valves simultaneously. We sought to develop and test a technique for quantitative assessment of mitral and aortic valve dynamics and coupling. Methods and Results— Matrix array transesophageal (Philips iE33) imaging was performed in 24 patients with normal valves who underwent clinically indicated transesophageal echocardiography. Custom software was used to detect and track the mitral and aortic annuli in 3D space throughout the cardiac cycle, allowing automated measurement of changes in mitral and aortic valve morphology. Mitral annulus surface area and aortic annulus projected area changed reciprocally over time. Mitral annulus surface area was 8.0�2.1 cm 2 at end-diastole and decreased to 7.7�2.1 cm 2 in systole, reaching its maximum (10.0�2.2 cm 2 ) at mitral valve opening. Aortic annulus projected area was 4.1�1.2 cm 2 at end-diastole, then increased during isovolumic contraction reaching its maximum (4.8�1.3 cm 2 ) in the first third of systole and its minimum (3.6�1.0 cm 2 ) during isovolumic relaxation. The angle between the mitral and aortic annuli was maximum (136�13�) at end-diastole and decreased to its minimum value (129�11�) during systole. Conclusions— This is the first study to report quantitative 3D assessment of the mitral and aortic valve dynamics from matrix array transesophageal images and describe the mitral-aortic coupling in a beating human heart. This ability may have impact on patient evaluation for valvular surgical interventions and prosthesis design.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3