1. From the Division of Pediatric Cardiology (M.K.F.), The Labatt Family Heart Center, Hospital for Sick Children and University of Toronto, Toronto, Ontario, Canada; Department of Cardiology (X.S., W.T., M.H., A.J.P., G.R.M.), Children's Hospital Boston and Harvard Medical School, Boston, Mass; and Division of Pediatric Cardiology (B.D.S.), Seattle Children's Hospital and University of Washington, Seattle, Wash.

Abstract

Background— Quantitative assessment and validation of left ventricular (LV) volumes and mass in neonates and infants with complex congenital heart disease (CHD) is important for clinical management but has not been undertaken. We compared matrix-array 3D echocardiography (3D echo) measurements of volumes, mass, and ejection fraction (EF) with those measured by cardiac MRI in young patients with CHD and small LVs because of either young age or LV hypoplasia. Methods and Results— Thirty-five patients aged <4 years (median, 0.8 years) undergoing MRI were prospectively enrolled. Three-dimensional echo was acquired immediately after MRI, and volume, mass, and EF measurements, using summation of discs methodology, were compared with MRI. Three-dimensional echo end-diastolic volume (24.4±15.7 versus 24.8±46.4 mL; P =0.01; intraclass correlation coefficient [ICC], 0.96) and end-systolic volume (12.3±8.6 versus 9.6±6.8 mL; P <0.001; ICC, 0.90) correlated with MRI with small mean differences (−0.49 mL [ P =0.6] and 2.7 mL [ P =0.001], respectively). Three-dimensional echo EF was smaller than MRI by 9.3% ( P <0.001), and 3D echo LV mass measurements were comparable to MRI (17.3±10.3 versus 17.6±12 g; P <0.77; ICC, 0.93), with a small mean difference (1.1 g; P =0.28). There was good intra- and interobserver reliability for all measurements. Conclusions— In neonates and infants with CHD and small LVs (age appropriate or hypoplastic), matrix-array 3D echo measurements of mass and volumes compare well with MRI, providing an important modality for ventricular size and performance analysis in these patients, particularly in those with left-side heart obstructive lesions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3