Validation of 3-Dimensional Speckle Tracking Imaging to Quantify Regional Myocardial Deformation

Author:

Seo Yoshihiro1,Ishizu Tomoko1,Enomoto Yoshiharu1,Sugimori Haruhiko1,Yamamoto Masayoshi1,Machino Tomoko1,Kawamura Ryo1,Aonuma Kazutaka1

Affiliation:

1. From the Cardiovascular Division (Y.S., T.I., M.Y., T.M., R.K., K.A.) and Department of Cardiovascular Surgery (Y.E., H.S.), Institute of Clinical Medicine, Graduate School of Comprehensive Human Science, University of Tsukuba, Ibaraki, Japan.

Abstract

Background— Three-dimensional speckle tracking imaging (3D-STI) has been introduced to assess regional left ventricular (LV) myocardial function. This study was designed to validate LV strain measurements by 3D-STI against data obtained by sonomicrometry. Methods and Results— In each of 10 anesthetized sheep, sonomicrometry crystals were implanted on the endocardium and epicardium at the LV basal, mid, and apical anterior and lateral walls. LV 3D-STI data sets were obtained from the apical approach at a frame rate of approximately 30 frames/s. Segmental longitudinal (LS), radial (RS), and circumferential strain (CS) measurements by 3D-STI were compared with those by sonomicrometry at baseline and during pharmacological stress tests (dobutamine and propranolol infusion) and acute myocardial ischemia induced by coronary artery occlusion. Data were available from 136 LS, 108 CS, and 175 RS measurements. Good correlations were observed between strain measurements by 3D-STI and those by sonomicrometry (LS: r =0.89, P <0.001; RS: r =0.84, P <0.001; CS: r =0.90, P <0.001). In each segmental study, significant correlations of the 3 strain components were observed (LS: r =0.65 to 0.68, P <0.001; RS: r =0.59 to 0.70, P <0.001; CS: r =0.71 to 0.78, P <0.001). Conclusions— The newly developed 3D-STI technique can estimate LV regional circumferential, longitudinal, and radial strain components with reasonable correlation to sonomicrometry data. This methodology could be applied clinically to assess alteration of myocardial function by accurately measuring strain in basal, mid, and apical LV segments, even during pharmacological and ischemic interventions. Therefore, 3D-STI appears to be a reliable tool to assess LV regional wall function.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3