Three‐Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta‐Analysis

Author:

Rong Lisa Q.1,Hameed Irbaz2,Salemi Arash2,Rahouma Mohamed2,Khan Faiza M.2,Wijeysundera Harindra C.3,Angiolillo Dominick J.4,Shore‐Lesserson Linda5,Biondi‐Zoccai Giuseppe67,Girardi Leonard N.2,Fremes Stephen E.3,Gaudino Mario2

Affiliation:

1. Department of Anesthesiology Weill Cornell Medicine New York NY

2. Department of Cardiothoracic Surgery Weill Cornell Medicine New York NY

3. Schulich Heart Centre Sunnybrook Health Science University of Toronto Canada

4. Division of Cardiology University of Florida College of Medicine Jacksonville FL

5. Department of Anesthesiology North Shore University Hospital Manhasset NY

6. Department of Medico‐Surgical Sciences and Biotechnologies Sapienza University of Rome Latina Italy

7. Mediterranea Cardiocentro Napoli Italy

Abstract

Background Transcatheter aortic valve replacement ( TAVR ) is the standard of care for many patients with severe symptomatic aortic stenosis and relies on accurate sizing of the aortic annulus. It has been suggested that 3‐dimensional transesophageal echocardiography (3D TEE) may be used instead of multidetector computed tomography ( MDCT ) for TAVR planning. This systematic review and meta‐analysis compared 3D TEE and MDCT for pre‐ TAVR measurements. Methods and Results A systematic literature search was performed. The primary outcome was the correlation coefficient between 3D TEE– and MDCT‐ measured annular area. Secondary outcomes were correlation coefficients for mean annular diameter, annular perimeter, and left ventricular outflow tract area; interobserver and intraobserver agreements; mean differences between 3D TEE and MDCT measurements; and pooled sensitivities, specificities, and receiver operating characteristic area under curve values of 3 D TEE and MDCT for discriminating post‐ TAVR paravalvular aortic regurgitation. A random effects model was used. Meta‐regression and leave‐one‐out analysis for the primary outcome were performed. Nineteen studies with a total of 1599 patients were included. Correlations between 3D TEE and MDCT annular area, annular perimeter, annular diameter, and left ventricular outflow tract area measurements were strong (0.86 [95% CI , 0.80–0.90]; 0.89 [ CI , 0.82–0.93]; 0.80 [ CI , 0.70–0.87]; and 0.78 [ CI , 0.61–0.88], respectively). Mean differences between 3 D TEE and MDCT between measurements were small and nonsignificant. Interobserver and intraobserver agreement and discriminatory abilities for paravalvular aortic regurgitation were good for both 3 D TEE and MDCT . Conclusions For pre‐ TAVR planning, 3 D TEE is comparable to MDCT . In patients with renal dysfunction, 3 D TEE may be potentially advantageous for TAVR measurements because of the lack of contrast exposure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 31 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3