Stability of heterogeneity of myocardial blood flow in normal awake baboons.

Author:

King R B,Bassingthwaighte J B,Hales J R,Rowell L B

Abstract

Regional myocardial blood flow has been thought to be relatively uniform, in accord with the singular function of myocardial cells. However, considerable spatial heterogeneity has been observed in the hearts of anesthetized animals and in isolated hearts. Studies were undertaken in a total of 13 baboons. Eleven were awake, healthy animals sitting in chairs at rest or feeding, some performed mild leg exercise (wheel turning), and others were subjected to whole body heating; two were anesthetized, methodological controls. Microspheres (15 +/- 3 micron diameter, 0.5 X 10(6)/kg body weight) were injected via a catheter into the apex of the left ventricle while arterial blood was sampled at a constant rate for calculating cardiac output. Microspheres with different labels were injected at six intervals of 20 minutes to several hours. On sacrifice, the hearts were sectioned into 204 locatable pieces (left ventricle, 168; right ventricle, 27; and atria, 9). Average resting myocardial flow was 2.1 +/- 0.2 ml/g per min (mean +/- SD, n = 11). Left and right ventricles and atria comprised 70 +/- 2% (n = 13), 20 +/- 2%, and 10 +/- 2% respectively of the total heart mass while receiving 80 +/- 3%, 16 +/- 2%, and 4 +/- 2% of the total myocardial flow. Thus, mean left ventricular flow was 114 +/- 5% of the average for the whole heart, right ventricular flow was 81 +/- 13%, and atrial flow was 41 +/- 13%. Myocardial flow heterogeneity was marked; in left ventricle, regional flows ranged from one-third to two times the mean, the relative dispersion (= standard deviation/mean) of regional flows, corrected for methodological scatter and temporal variation, was 0.33 +/- 0.06 (n = 67) in the whole heart, 0.26 +/- 0.07 in left ventricle, 0.32 +/- 0.11 in right ventricle, and 0.22 +/- 0.19 in the atria. The pattern of regional flows in each heart tended to remain stable with time. In each piece averaged over time, the relative dispersion due to temporal heterogeneity was 0.11 +/- 0.03 (n = 2040) in the whole heart, 0.09 +/- 0.03 in the left ventricle, 0.15 +/- 0.05 in the right ventricle, and 0.23 +/- 0.06 in the atria. The conclusion is that the degree of spatial heterogeneity of local myocardial flows in conscious primates is similar to that of anesthetized animals and isolated hearts, and is much greater than that due to temporal fluctuations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference39 articles.

1. Ischemic Areas in Perfused Rat Hearts: Measurement by NADH Fluorescence Photography

2. Physiology and theory of tracer washout techniques for the estimation of myocardial blood flow: Flow estimation from tracer washout

3. Bassingthwaighte JB (1982) Calculation of transorgan transport functions for a multipath capillary-tissue system. Report UW/ BIOENG 82/1 (available from NTIS Springfield VA 22161)

4. Bassingthwaighte JB Goresky CA (1984) Modeling in the analysis of solute and water exchange in the microvascularure. In Handbook of Physiology sec II The Cardiovascular System vol 4 part 1 The Microcirculation Washington D.C. edited by EM Renkin CC Michel. American Physiological Society pp 549-626

5. Estimation of coronary blood flow by washout of diffusible indicators;Bassingthwaighte JB;Ore Res,1968

Cited by 259 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3