Optimal Use of Vasodilators for Diagnosis of Microvascular Angina in the Cardiac Catheterization Laboratory

Author:

Rahman Haseeb1,Demir Ozan M.1,Ryan Matthew1,McConkey Hannah1,Scannell Cian2,Ellis Howard1,Webb Andrew1,Chiribiri Amedeo2,Perera Divaka1ORCID

Affiliation:

1. School of Cardiovascular Medicine and Sciences, British Heart Foundation Centre of Excellence and National Institute for Health Research Biomedical Research Centre (H.R., O.M.D., M.R., H.M., H.E., A.W., D.P.), King’s College London, United Kingdom.

2. School of Biomedical Engineering and Imaging Sciences (C.S., A.C.), King’s College London, United Kingdom.

Abstract

Background: Among patients with angina and nonobstructive coronary artery disease, those with coronary microvascular dysfunction have a poor outcome. Coronary microvascular dysfunction is usually diagnosed by assessing flow reserve with an endothelium-independent vasodilator like adenosine, but the optimal diagnostic threshold is unclear. Furthermore, the incremental value of testing endothelial function has never been assessed before. We sought to determine what pharmacological thresholds correspond to exercise pathophysiology and myocardial ischemia in patients with coronary microvascular dysfunction. Methods: Patients with angina and nonobstructive coronary artery disease underwent simultaneous acquisition of coronary pressure and flow during rest, supine bicycle exercise, and pharmacological vasodilatation with adenosine and acetylcholine. Adenosine and acetylcholine coronary flow reserve were calculated as vasodilator/resting coronary blood flow (CFR and AchFR, respectively). Coronary wave intensity analysis was used to quantify the proportion of accelerating wave energy; a normal exercise response was defined as an increase in accelerating wave energy from rest to peak exercise. Ischemia was assessed by quantitative 3-Tesla stress perfusion cardiac magnetic resonance imaging and dichotomously defined by a hyperemic endo-epicardial gradient <1.0. Results: Ninety patients were enrolled (58±10 years, 77% female). Area under the curve using receiver-operating characteristic analysis demonstrated optimal CFR and AchFR thresholds for identifying exercise pathophysiology and ischemia as 2.6 and 1.5, with positive and negative predictive values of 91% and 86%, respectively. Fifty-eight percent had an abnormal CFR (of which 96% also had an abnormal AchFR). Of those with a normal CFR, 53% had an abnormal AchFR, and 47% had a normal AchFR; ischemia rates were 83%, 63%, and 14%, respectively. Conclusions: The optimal CFR and AchFR diagnostic thresholds are 2.6 and 1.5, with high-positive and negative predictive values, respectively. A normal CFR value should prompt the measurement of AchFR. A stepwise algorithm incorporating both vasodilators can accurately identify an ischemic cause in patients with nonobstructive coronary artery disease.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3