Bilateral Internal Thoracic Artery Configuration for Coronary Artery Bypass Surgery

Author:

Glineur David1,Boodhwani Munir1,Hanet Claude1,de Kerchove Laurent1,Navarra Emiliano1,Astarci Parla1,Noirhomme Philippe1,El Khoury Gebrine1

Affiliation:

1. From the Department of Cardiovascular Medicine and Surgery, Cliniques Universitaires St Luc, Brussels, Belgium (D.G., M.B., C.H., L.d.K., E.N., P.A., P.N., G.E.K.); and Division of Cardiac Surgery, University of Ottawa Heart institute, Ottawa, Canada (D.G., M.B.).

Abstract

Background— Bilateral internal thoracic arteries (BITA) have demonstrated superior patency and improved survival in patients undergoing coronary artery bypass grafting. However, the optimal configuration for BITA utilization and its effect on long-term outcome remains uncertain. Methods and Results— We randomly assigned 304 patients undergoing coronary artery bypass grafting using BITA to either in situ or Y grafting configurations. The primary end point was 3-year angiographic patency. Secondary end points included major adverse cardiac and cerebrovascular events (ie, death from any cause, stroke, myocardial infarction, or repeat revascularization) at 7 years. More coronary targets were able to be revascularized using internal thoracic arteries in patients randomized to Y grafting versus in situ group (3.2±0.8 versus 2.4±0.5 arteries/patient; P <0.01). The primary end point did not show significant differences in graft patency between groups. Secondary end points occurred more frequently in the in situ group ( P =0.03), with 7-year rates of 34±10% in the in situ and 25±12% in the Y grafting groups, driven largely by a higher incidence of repeat revascularization in the in situ group (14±4.5% versus 7.4±3.2% at 7 years; P =0.009). There were no significant differences in hospital mortality or morbidity or in late survival, myocardial infarction, or stroke between groups. Conclusions— Three-year systematic angiographic follow-up revealed no significant difference in graft patency between the 2 BITA configurations. However, compared with in situ configuration, the use of BITA in a Y grafting configuration results in lower rates of major adverse cardiovascular and cerebrovascular events at 7 years. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT01666366.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3