Unselected Use of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Coronary Revascularization

Author:

Yamaji Kyohei1,Zanchin Thomas1,Zanchin Christian1,Stortecky Stefan1,Koskinas Konstantinos C.1,Hunziker Lukas1,Praz Fabien1,Blöchlinger Stefan1,Moro Christina1,Moschovitis Aris1,Seiler Christian1,Valgimigli Marco1,Billinger Michael1,Pilgrim Thomas1,Heg Dik2,Windecker Stephan1,Räber Lorenz1

Affiliation:

1. Swiss Cardiovascular Center Bern, Department of Cardiology, Bern University Hospital, Switzerland (K.Y., T.Z., C.Z., S.S., K.C.K., L.H., F.P., S.B., C.M., A.M., C.S., M.V., M.B., T.P., S.W., L.R.).

2. Institute of Social and Preventive Medicine and Clinical Trials Unit, University of Bern, Switzerland (D.H.).

Abstract

Background: Biodegradable polymer sirolimus-eluting stents (BP-SESs) have been reported to be noninferior compared with durable polymer everolimus-eluting stents (DP-EES) in a randomized clinical trial. We sought to compare the efficacy and safety of an ultrathin strut BP-SES with a DP-EES in an all-comers population. Methods and Results: Among 7640 consecutive patients who underwent percutaneous coronary intervention between March 2011 and June 2015, 4638 patients were exclusively treated with BP-SES (N=1896; 3137 lesions) or DP-EES (N=2742; 4468 lesions). After propensity score matching within strata of clinical indications, the final study population consisted of 2902 matched patients (BP-SES 2406 lesions and DP-EES 2368 lesions). The primary device-oriented composite end point (DOCE) included cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1 year. BP-SES (6.9%) was noninferior to DP-EES (8.0%) with respect to device-oriented composite end point (hazard ratio [HR], 0.85; 95% CI, 0.65–1.11; P for noninferiority <0.001; P for superiority=0.24). No differences in cardiac death (BP-SES, 2.3% versus DP-EES, 3.0%; HR, 0.76; 95% CI, 0.49–1.20; P =0.25), myocardial infarction (BP-SES, 4.6% versus DP-EES, 4.6%; HR, 1.00; 95% CI, 0.71–1.40; P =0.99), or target lesion revascularization (BP-SES, 2.8% versus DP-EES, 2.5%; HR, 1.11; 95% CI, 0.71–1.74; P =0.65) were observed. The rate of periprocedural myocardial infarction was comparable between the 2 groups (2.1% versus 2.2%; HR, 0.97; 95% CI, 0.59–1.58; P =0.89). The rate of definite stent thrombosis was similarly low throughout 1 year (BP-SES, 0.8% versus DP-EES, 0.8%; HR, 1.00; 95% CI, 0.45–2.22; P =1.00). Conclusions: In a consecutively enrolled percutaneous coronary intervention population reflecting routine clinical practice, BP-SES was noninferior to DP-EES for device-oriented composite end point at 1 year. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02241291.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3