Pharmacokinetics of Sirolimus-Eluting Stents Implanted in the Neonatal Arterial Duct

Author:

Lee Kyong-Jin1,Seto Winnie1,Benson Lee1,Chaturvedi Rajiv R.1

Affiliation:

1. From The Labatt Family Heart Centre, Division of Cardiology (K.-J.L., L.B., R.R.C.) and the Department of Pharmacy (W.S.), The Hospital for Sick Children, University of Toronto School of Medicine, Toronto, Canada.

Abstract

Background— Sirolimus-eluting stents may have clinical advantages over bare-metal stents in the extremely proliferative environment of the neonatal arterial duct. However, sirolimus has immunosuppressive actions and little is known regarding sirolimus pharmacokinetics in the newborn. Methods and Results— This is a retrospective review of sirolimus pharmacokinetics in neonates who underwent sirolimus-eluting stent implantation in the arterial duct for pulmonary blood flow augmentation. Pharmacokinetic parameters were obtained by noncompartmental analysis and by a Bayesian one-compartment nonlinear mixed model. Nine neonates received a single sirolimus-eluting stent with a total sirolimus dose of 245 μg (n=1), 194 μg (n=5), or 143 μg (n=3). Peak sirolimus concentrations were 13.6±4.5 μg/L (24.8 μg/L highest) and clearance was 0.042±0.03 L/hour (noncompartmental analysis) and 0.051 L/hour (95% credible intervals 0.037–0.069, nonlinear mixed model). Sirolimus remained >5 μg/L, the trough level used in oral immunosuppressive therapy, for (95% credible interval) 15.9 (11.4, 22.8), 12.9 (7.6, 19.0), and 8.4 (2.3, 14.5) days for the 245, 194, and 143 μg sirolimus dose stents, respectively. Estimates of the duration of systemic immunosuppression are provided for combinations of 2 stents. Conclusions— In neonates after sirolimus-eluting stent implantation, peak sirolimus levels were 20× higher and clearance 30× lower than previously reported in older children and adults. Sirolimus levels were within the immunosuppressive range for a prolonged period, but with no observable clinically significant adverse outcomes.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Interventional cardiac catheterization;Nadas' Pediatric Cardiology;2025

2. Impact of Drug Elution on Infectious Outcomes after Ductal Stenting in Newborns;Pediatric Cardiology;2024-09-05

3. In vivo biocompatibility of a new hydrophobic coated Al/Al2O3 nanowire surface on stents;Cardiovascular Revascularization Medicine;2024-08

4. Stenting of the Patent Ductus Arteriosus;Interventional Cardiology Clinics;2024-07

5. Interventions for Univentricular Hearts;Pediatric and Congenital Cardiology, Cardiac Surgery and Intensive Care;2024