Clinical and Echocardiographic Outcomes Following Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement

Author:

Mohananey Divyanshu1,Jobanputra Yash1,Kumar Arnav1,Krishnaswamy Amar1,Mick Stephanie1,White Jonathon M.1,Kapadia Samir R.1

Affiliation:

1. From the Department of Hospital Medicine (D.M., A.K.), Department of Cardiovascular Medicine (Y.J., A.K., J.M.W., S.R.K.), and Department of Cadiothoracic Surgery (S.M.), Cleveland Clinic, OH.

Abstract

Background— Transcatheter aortic valve replacement has become the procedure of choice for inoperable, high-risk, and many intermediate-risk patients with aortic stenosis. Conduction abnormalities are a common finding after transcatheter aortic valve replacement and often result in permanent pacemaker (PPM) implantation. Data pertaining to the clinical impact of PPM implantation are controversial. We used meta-analysis techniques to summarize the effect of PPM implantation on clinical and echocardiographic outcomes after transcatheter aortic valve replacement. Methods and Results— Data were summarized as Mantel–Haenszel relative risk (RR) and 95% confidence intervals (CIs) for dichotomous variables and as standardized mean difference and 95% CI for continuous variables We used the Higgins I 2 statistic to evaluate heterogeneity. We found that patients with and without PPM have similar all-cause mortality (RR, 0.85; 95% CI, 0.70–1.03), cardiovascular mortality (RR, 0.84; 95% CI, 0.59–1.18), myocardial infarction (RR, 0.47; 95% CI, 0.20–1.11), and stroke (RR, 1.26; 95% CI, 0.70–2.26) at 30 days. The groups were also comparable in all-cause mortality (RR, 1.03; 95% CI, 0.92–1.16), cardiovascular mortality (RR, 0.69; 95% CI, 0.39–1.24), myocardial infarction (RR, 0.58; 95% CI, 0.30–1.13), and stroke (RR, 0.70; 95% CI, 0.47–1.04) at 1 year. We observed that the improvement in left ventricular ejection fraction was significantly greater in the patients without PPM (standardized mean difference, 0.22; 95% CI, 0.12–0.32). Conclusions— PPM implantation is not associated with increased risk of all-cause mortality, cardiovascular mortality, stroke, or myocardial infarction both at short- and long-term follow-up. However, PPM is associated with impaired left ventricular ejection fraction recovery post-transcatheter aortic valve replacement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3