Drug-Eluting Stents in Bifurcations

Author:

Guérin Patrice1,Pilet Paul1,Finet Gérard1,Gouëffic Yann1,N'Guyen Jean Michel1,Crochet Dominique1,Tijou Isabelle1,Pacaud Pierre1,Loirand Gervaise1

Affiliation:

1. From the INSERM (P.G., Y.G., D.C., I.T., P.P., G.L.), UMR915, l'institut du thorax, Nantes, France; CHU Nantes (P.G., D.C., G.L.), l'institut du thorax, Service d'Hémodynamique, Nantes, France; Centre Commun de Microscopie Electronique (P.P.), Nantes, France; Department of Interventional Cardiology (G.F.), CHU Lyon, Lyon, France; INSERM (G.F.), UMR886, Lyon, France; CHU Nantes (Y.G.), l'institut du thorax, Service de Chirurgie Vasculaire, Nantes, France; Université de Nantes (Y.G., D.C., P.P., G.L...

Abstract

Background— The use of a drug-eluting stent (DES) has strongly limited the incidence of in-stent restenosis in bifurcation lesions; nevertheless, restenosis still remains a problem at the origin of the bifurcation side branch. The aim of this study is to analyze the consequences of the kissing postdilatation technique on 5 DESs, using microfocus x-ray computerized tomography and scanning electron microscopy. Methods and Results— Five different DESs (Cypher, Cypher Select, Endeavor, Taxus Express, and Taxus Liberté) were deployed using kissing postdilatation protocols in a bench-top model. For all types of DES, microfocus x-ray computerized tomography analysis showed that (1) kissing postdilatation of the stent by 2 coaxial balloons caused elliptic deformation in the proximal segment and (2) kissing postdilatation technique reduced the ratio of potential metal to artery (manufacturer’s data/calculated ratio [%]: Cypher, 12.7/8.8; Cypher Select, 13.5/10.2; Endeavor, 19.0/13.3; Taxus Express, 20.5/4.7; Taxus Liberté, 17.9/12.5) and the potential drug application to area in the proximal segment, including the ostial struts (struts adjacent to and lying around the side branch ostium) (manufacturer’s data/calculated drug application [μg/mm 2 ]: Cypher, 1.4/1.0; Cypher Select, 1.4/1.1; Endeavor, 1.6/1.1; Taxus Express, 1.0/0.7; Taxus Liberté, 1.0/0.7). Scanning electron microscopy analysis showed a significantly greater coating damage to the ostial struts in all stents evaluated ( P <0.05). Conclusions— Commercially available DESs subjected to simultaneous kissing balloon postdilatation in an unconstrained model may contribute to side branch ostial restenosis by proximal segment elliptic deformation and damage to the polymer coating.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3