Optical Coherence Tomography Findings in Lesions After Sirolimus-Eluting Stent Implantation With Peri-Stent Contrast Staining

Author:

Tada Takeshi1,Kadota Kazushige1,Hosogi Shingo1,Kubo Shunsuke1,Ozaki Masatomo1,Yoshino Mitsuru1,Miyake Koshi1,Eguchi Haruki1,Ohashi Noriyuki1,Hayakawa Yuki1,Saito Naoki1,Otsuru Suguru1,Hasegawa Daiji1,Shigemoto Yoshikazu1,Habara Seiji1,Imai Masao1,Tanaka Hiroyuki1,Fuku Yasushi1,Oka Naoki1,Kato Harumi1,Yamamoto Hiroyuki1,Fujii Satoki1,Goto Tsuyoshi1,Mitsudo Kazuaki1

Affiliation:

1. From the Department of Cardiovascular Medicine, Kurashiki Central Hospital, Kurashiki, Japan (T.T., K.K., S.K., M.O., M.Y., K.M., H.E., N.O., Y.H., N.S., S.O., D.H., Y.S., S.H., H.T., Y.F., N.O., H.K., H.Y., S.F., T.G., K.M.); Department of Cardiovascular Medicine, Kochi Health Sciences Center, Kochi, Japan (S.H.); and Department of Cardiovascular Medicine, Graduated School of Medicine, Kyoto University, Kyoto, Japan (M.I.).

Abstract

Background— We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. Methods and Results— Between May 2008 and March 2010, we performed optical coherence tomography for 90 in-stent restenosis lesions after sirolimus-eluting stent implantation. We found PSS in 20 of the 90 lesions by coronary angiography. The differences in optical coherence tomography findings, including incomplete stent apposition, multiple interstrut hollows (MIH), strut coverage, and thrombus, were compared between lesions with PSS and those without PSS. PSS is defined as contrast staining outside the stent contour extending to >20% of the stent diameter measured by quantitative coronary angiography. MIH is defined as multiple hollows (the maximum depth >0.5 mm) existing between and outside well-apposed stent struts. Both incomplete stent apposition (60.0% versus 10%; P <0.001) and MIH (85.0% versus 25.7%; P <0.001) were frequently observed in lesions with PSS than in lesions without PSS. Among the 20 lesions with PSS, there was only 1 lesion in which we found neither MIH nor incomplete stent apposition, but only minor dissection. Uncovered struts (11.6% versus 3.9%; P =0.001), malapposed struts (2.0% versus 0.0%; P <0.001), and red thrombus (35% versus 10%; P =0.012) were frequently observed in lesions with PSS than in lesions without PSS. Conclusions— PSS might be closely associated with 2 different optical coherence tomography findings, MIH and incomplete stent apposition, in lesions after sirolimus-eluting stent implantation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3