Prevalence of Tibial Artery and Pedal Arch Patency by Angiography in Patients With Critical Limb Ischemia and Noncompressible Ankle Brachial Index

Author:

Randhawa Mandeep Singh1,Reed Grant W.1,Grafmiller Kevin1,Gornik Heather L.1,Shishehbor Mehdi H.1

Affiliation:

1. From the Department of Cardiovascular Medicine, Cleveland Clinic, OH; and School of Medicine, Case Western Reserve University, Cleveland, OH.

Abstract

Background— Approximately 20% of patients undergoing ankle brachial index testing for critical limb ischemia have noncompressible vessels because of tibial artery calcification. This represents a clinical challenge in determining tibial artery patency. We sought to identify the prevalence of tibial artery and pedal arch patency by angiography in these patients. Methods and Results— One hundred twenty-five limbs (of 89 patients) with critical limb ischemia and ankle brachial index ≥1.4 who underwent lower extremity angiograms within 1 year were included. Reviewers of angiography were blinded to results of physiological testing. Tibial artery vessels were classified as completely occluded, significantly stenosed (≥50%), or patent (<50% stenosis). The sensitivity of toe brachial index and pulse volume recording to predict tibial artery disease was also determined. Of 125 limbs with noncompressible ankle brachial index, 72 (57.6%) anterior tibial and 80 (64%) posterior tibial arteries were occluded. Another 23 (18.4%) anterior tibial and 13 (10.4%) posterior tibial arteries had ≥50% stenosis. Pulse volume recording was moderate to severely dampened in 54 of 119 (45.4%) limbs. Toe brachial index <0.7 was found in 75 of 83 (90.4%) limbs. Moderate to severe pulse volume recording dampening was 43.6% sensitive, whereas toe brachial index <0.7 was 89.7% sensitive in diagnosing occluded or significantly stenotic tibial artery disease. The pedal arch was absent or incomplete in 86 of 103 (83.5%) limbs. Conclusions— Among patients with critical limb ischemia and noncompressible ankle brachial index results, the prevalence of occlusive tibial and pedal arch disease is very high. Toe brachial index <0.7 is more sensitive in diagnosing occluded and significantly stenotic tibial artery disease in these patients compared with ankle pulse volume recording.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3