Functional Assessment of Coronary Artery Disease in Patients Undergoing Transcatheter Aortic Valve Implantation

Author:

Pesarini Gabriele1,Scarsini Roberto1,Zivelonghi Carlo1,Piccoli Anna1,Gambaro Alessia1,Gottin Leonardo1,Rossi Andrea1,Ferrero Valeria1,Vassanelli Corrado1,Ribichini Flavio1

Affiliation:

1. From the Division of Cardiology, Department of Medicine, School of Medicine (G.P., R.S., C.Z., A.P., A.G., A.R., V.F., C.V., F.R.) and Department of Anesthesia and Intensive Care (L.G.), University of Verona, Italy.

Abstract

Background— Aortic valve stenosis may influence fractional flow reserve (FFR) of concomitant coronary artery disease by causing hypertrophy and reducing the vasodilatory reserve of the coronary circulation. We sought to investigate whether FFR values might change after valve replacement. Methods and Results— The functional relevance of 133 coronary lesions was assessed by FFR in 54 patients with severe aortic valve stenosis before and after transcatheter aortic valve implantation (TAVI) during the same procedure. A linear mixed model was used to verify the interaction of TAVI effect with the FFR values. No significant overall change in FFR values was found before and after the aortic valve stenosis removal (0.89±0.10 versus 0.89±0.13; P =0.73). A different trend in FFR groups (positive if ≤0.8; negative if >0.8) was found after TAVI ( P for interaction <0.001). Positive FFR values worsened after TAVI (0.71±0.11 versus 0.66±0.14). Conversely, negative FFR values improved after TAVI (0.92±0.06 versus 0.93±0.07). Similarly, FFR values in coronary arteries with lesions presenting percent diameter stenosis >50 worsened after TAVI (0.84±0.12 versus 0.82±0.16; P =0.02), whereas FFR values in arteries with mild lesions (percent diameter stenosis <50) tended toward improvement after TAVI (0.90±0.07 versus 0.91±0.09; P =0.69). Functional FFR variations after TAVI changed the indication to treat the coronary stenosis in 8 of 133 (6%) lesions. Conclusions— Coronary hemodynamics are influenced by aortic valve stenosis removal. Nevertheless, FFR variations after TAVI are minor and crossed the diagnostic cutoff of 0.8 in a small number of patients after valve replacement. Borderline coronary lesions might become functionally significant after valve replacement, although FFR-guided interventions were infrequent even in patients with angiographically significant lesions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3