Comparison of Acute Thrombogenicity for Metallic and Polymeric Bioabsorbable Scaffolds

Author:

Waksman Ron1,Lipinski Michael J.1,Acampado Eduardo1,Cheng Qi1,Adams Lila1,Torii Sho1,Gai Jiaxiang1,Torguson Rebecca1,Hellinga David M.1,Westman Peter C.1,Joner Michael1,Zumstein Philine1,Kolodgie Frank D.1,Virmani Renu1

Affiliation:

1. From the Section of Interventional Cardiology, MedStar Washington Hospital Center, DC (R.W., M.J.L., J.G., R.T., D.M.H., P.C.W.); CVPath Institute, Inc, Gaithersburg, MD (E.A., Q.C., L.A., S.T., M.J., F.D.K., R.V.); and Biotronik AG, Bülach, Switzerland (P.Z.).

Abstract

Background— A comparison in acute thrombogenicity between the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold and the Absorb bioresorbable vascular scaffold has not been performed. This study assessed acute thrombogenicity of Magmaris compared with Absorb and the Orsiro hybrid drug-eluting stent in a porcine arteriovenous shunt model. Methods and Results— An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to SYLGARD tubing containing the Magmaris, Absorb, and Orsiro scaffolds/stents and allowed to run in the shunt for a maximum of 1 hour. Twelve shunts (2 shunt runs per pig) were run comparing the 3 scaffolds in alternating order. Nested generalized linear mixed models were used to compare variables between scaffold groups while adjusting for variability between shunt runs. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that both Magmaris (3.0%) and Orsiro (4.6%) had less platelet coverage of the total scaffold compared with Absorb (21.8%). Scanning electron microscopy demonstrated significantly less thrombus deposition to Magmaris as a percentage of the total scaffold compared with Absorb (5.0% versus 16.1%, P =0.02). Magmaris had significantly less PM-1–positive neutrophil and CD14-positive monocyte adherence compared with both Orsiro and Absorb. Orsiro had significantly less monocyte deposition compared with Absorb. Conclusions— Despite a similar scaffold strut thickness, the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold was significantly less thrombogenic compared with the Absorb bioresorbable vascular scaffold in an ex vivo porcine arteriovenous shunt model. Further studies are needed to determine whether the reduced thrombogenicity of Magmaris will result in reductions in major cardiovascular events.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 98 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献