Drug-Eluting Stents Versus Bare-Metal Stents for Off-Label Indications

Author:

Austin David1,Oldroyd Keith G.1,McConnachie Alex1,Slack Rachel1,Eteiba Hany1,Flapan Andrew D.1,Jennings Kevin P.1,Northcote Robin J.1,Pell Alastair C.H.1,Starkey Ian R.1,Pell Jill P.1

Affiliation:

1. From the Section of Public Health and Health Policy (D.A., R.S., J.P.P.) and Robertson Centre for Biostatistics (A.M.), University of Glasgow; Western Infirmary (K.G.O.); Glasgow Royal Infirmary (H.E.); Victoria Infirmary (R.J.N.), Glasgow; Edinburgh Royal Infirmary (A.D.F.); Western General Hospital (I.R.S.), Edinburgh; Aberdeen Royal Infirmary (K.P.J.), Aberdeen; and Monklands Hospital (A.C.H.P.), Airdrie, Lanarkshire, United Kingdom.

Abstract

Background— The US Food and Drug Administration recently concluded that data on off-label drug-eluting stent (DES) safety are limited. However, in actual clinical practice, DES are often used for off-label indications, and observational studies demonstrate that complications are higher when compared with on-label use. We aimed to determine whether clinical outcomes differ after DES and bare-metal stent implantation in a patient cohort defined by DES off-label indications. Methods and Results— We used the national revascularization registry in Scotland to identify patients who underwent coronary stenting for an off-label indication between January 2003 and September 2005. Individual-level linkage to comprehensive national admission and death databases was used to ascertain the end points of death, myocardial infarction, and target-vessel revascularization. We calculated propensity scores on the basis of clinical, demographic, and angiographic variables and matched DES to bare-metal stents on a 1:1 basis. The final study population consisted of 1642 patients, well matched for important covariables at baseline. Event-free survival was calculated over 24 months with the Kaplan-Meier method. All-cause death was more common after bare-metal stent implantation during follow-up (7.7% versus 6.6%; hazard ratio 0.63; 95% confidence interval, 0.40 to 0.99; P =0.04). No difference in the rates of myocardial infarction were noted (7.3% versus 7.5%; hazard ratio 1.02; 95% confidence interval, 0.69 to 1.54; P =0.92). Target-vessel revascularization was reduced in patients treated with DES (13.9% versus 10.7%; hazard ratio 0.67; 95% confidence interval, 0.49 to 0.93; P =0.02). Conclusions— At 24 months, patients treated with DES for off-label indications had lower rates of death and target-vessel revascularization and similar rates of myocardial infarction, as compared with patients treated with bare-metal stents.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Reference37 articles.

1. Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary Artery

2. One-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent

3. US Food and Drug Administration. CYPHER Sirolimus-eluting Coronary Stent on RAPTOR Over-the-Wire Delivery System or RAPTORRAIL Rapid Exchange Delivery System - P020026. Available at: http://www.fda.gov/cdrh/pdf2/P020026.html. Accessed January 8 2008.

4. US Food and Drug Administration. TAXUS Express 2 Paclitaxel-Eluting Coronary Stent System (Monorail and Over-the-Wire) - P030025. Available at: http://www.fda.gov/cdrh/pdf3/P030025.html. Accessed January 8 2008.

5. Cause of death with bare metal and sirolimus-eluting stents

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3