1. From the Department of Cardiology (S.S., P.K., R.E.), West German Heart Center, Essen, Germany; the Department of Medicine (L.B.), Montreal Heart Institute, Montréal, Canada; the Department of Cardiology (L.P., V.L., P.L.), University Hospital of Liège, Liège, Belgium; the Department of Cardiology (R.H., P.S.), R-WTH University Hospital Aachen, Aachen, Germany; the Cardiovascular Center OLV Ziekenhuis (J.B., M.V.), Aalst, Belgium; Medical College of Wisconsin (D.M.), Milwaukee, Wis; and...

Abstract

Background— We assessed the safety and feasibility of permanent implantation of a novel coronary sinus mitral repair device (PTMA, Viacor Inc). Methods and Results— Symptomatic (New York Heart Association class 2 or 3) patients with primarily functional mitral regurgitation (MR) were included. A diagnostic PTMA procedure was performed in the coronary sinus venous continuity. MR was assessed and the PTMA device adjusted to optimize efficacy. If MR reduction (≥1 grade) was observed, placement of a PTMA implant was attempted. Implanted patients were evaluated with echocardiographic, quality of life, and exercise capacity metrics. Nineteen patients received a diagnostic PTMA study. Diagnostic PTMA was effective in 13 patients (MR grade 3.2�0.6 reduced to 2.0�1.0), and PTMA implants were placed in 9 patients. Four devices were removed uneventfully (7, 84, 197, and 216 days), 3 for annuloplasty surgery due to observed PTMA device migration and/or diminished efficacy. No procedure or device-related major adverse events with permanent sequela were observed in any of the diagnostic or implant patients. Sustained reductions of mitral annulus septal-lateral dimension from 3D echo reconstruction dimensions were observed (4.0�1.2 mm at 3 months). Conclusions— Percutaneous implantation of the PTMA device is feasible and safe. Acute results demonstrate a possibly meaningful reduction of MR in responding patients. Sustained favorable geometric modification of the mitral annulus has been observed, though reduction of MR has been limited. The PTMA method warrants continued evaluation and development.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3