Atrial reentry around an anatomic barrier with a partially refractory excitable gap. A canine model of atrial flutter.

Author:

Frame L H,Page R L,Hoffman B F

Abstract

We have characterized, in dogs, a model of inducible regular atrial tachycardia that resembles atrial flutter. The model involves creating a Y-shaped lesion comprised of an intercaval incision and a connected incision across the right atrium. It is suitable for serial studies of the effects of pacing or antiarrhythmic drugs in chronically instrumented animals studied in the awake state for at least several months. The postoperative cycle length of the induced tachycardia varies from 143 to 188 msec, depending on the size of the dog. The tachycardia cycle length was consistent for each dog, and the rhythm--once induced--was very stable until terminated by pacing. The mechanism of the tachycardia was reentry due to circus movement based on the ability to induce and terminate it by premature impulses or overdrive, the ability to reset the tachycardia by single premature stimuli, the pattern of entrainment during overdrive stimulation, and the ability to terminate the tachycardia by interrupting the conduction pathway. The window of reset determined by the range of coupling intervals of premature stimuli that were able to enter and reset the tachycardia ranged from 56 to 82 msec. There appears to be incomplete recovery of excitability by the end of the excitable gap as evidenced by the fact that even late premature impulses that enter the reentrant circuit conduct more slowly than the tachycardia impulse, and because stimulation of muscarinic receptors that shortens the duration of the action potential and refractoriness also reduces the cycle length of the tachycardia. Epicardial and endocardial activation mapping during tachycardia showed the reentrant pathway does not merely encircle the lesion, particularly over the left atrial epicardium near the intercaval lesion. Rather, the impulse appears to travel around the atrial tissue just above the tricuspid ring, including a portion that travels through the right side of the lower intraatrial septum. Thus, the model involves circus movement around an anatomic barrier through normal tissue that contains no depressed segments. During the circus movement, there is a relatively long excitable gap during which there is incomplete recovery of excitability. This model should be useful for studies of the mechanism of antiarrhythmic drug action and the responses to premature stimulation in this particular subclass of reentrant rhythms, and for comparison with the behavior and responses of other forms of reentry.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 213 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3