With the use of a new ultrasonic volume flow meter (VFM), over 8000 measurements of common carotid blood flow were made in 120 normal control subjects and 550 patients with various neurological disease. The accuracy of the flow meter in measuring blood flow on an experimental model ranged from 93 to 97%. In normal subjects, common carotid blood flow varies with age. It increased from newborn to age 20 and gradually decreased thereafter. In normal healthy subjects, the flow varies within +/- 6.7% (2SD) at one sitting (intrasession) and +/- 21.2% (2SD) from week to week (intersession study). Carotid blood flow varies linearly with PaCO2 and increased markedly in response to endotracheal intubation. In healthy adults, the flow ratio between the two common carotid arteries is 1.07 +/- 0.052. This ratio increases in patients with transient ischemic attacks to 1.28 +/- 0.23 (p less than 0.05) and in patients with intracranial space occupying lesions to 1.46 +/- 0.39, (p less than 0.01). In 26 consecutive cases of carotid endarterectomies, the preoperative common carotid blood volume flow was 5.1 +/- 1.0 cc/sec. All cases preoperatively had at least 30% stenosis and ranged from 30 to 100% stenosis. The carotid blood volume was significantly increased post-operatively (p less than 0.001). The overall accuracy in detecting carotid and cerebral arterial disease is 89% with sensitivity of 96% and the specificity of 71%. Our clinical experience indicates that this device is not only a valuable noninvasive diagnostic tool for evaluation of carotid disease but also appears to be useful in assessing cerebral blood flow.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Reference29 articles.

1. Determination of volume of arterial blood flow by an ultrasonic device

2. Furuhata H Kanno R Kodiara K etal: Development of ultrasonic volume flow meter. Proceedings of Japanese Soc Med Engineering and Biomed. Engineering 2: D. 33 1978

3. Duck FS Hudson CJ: A practical method of eliminating the angular dependence of Doppler flow measurements. Abstracts of 10th ICMBE 15: 1973

4. A phase-locked echo tracking system for recording arterial diameter changes in vivo.

5. Kodaira K Furuhata H Shitaji E etal: Development of noninvasive cerebral blood flow meter. Medical Technological Development Foundation (Jap) 95: 1979

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3