Multicenter validation study of real-time ultrasonography, arteriography, and pathology: pathologic evaluation of carotid endarterectomy specimens.

Author:

Schenk E A1,Bond M G1,Aretz T H1,Angelo J N1,Choi H Y1,Rynalski T1,Gustafson N F1,Berson A S1,Ricotta J J1,Goodison M W1

Affiliation:

1. Department of Pathology, University of Rochester Medical Center, New York 14642.

Abstract

The morphologic description and measurements of endarterectomy specimens are usually believed to be accurate and are used as the gold standard against which the findings of diagnostic procedures are judged. Pathology data on 289 endarterectomy specimens from five participating centers and the corresponding angiography and B-mode ultrasonography data provided a basis for scrutinizing the validity of using the morphologic measurements as a standard. Discrepancies of greater than 1 mm between pathology and angiography measurements of minimum residual lumen occurred in 35% of the cases and between pathology and B-mode ultrasonography measurements in 64% of the cases. Discrepancies of greater than 1 mm between pathology- and angiography-measured lesion width occurred in 81% of the cases and between pathology and B-mode ultrasonography measurements in 64% of the cases. The cases representing mismatches of greater than 1 mm at one participating center were subjected to a rigorous review, with remeasurement of all morphologic features, in an attempt to explain the discrepancies. Various types of artifactual distortion of the specimens, the presence of slit-like and occluded lumens that were likely related to loss of perfusion pressure, and an inability to match planes of interrogation used in angiography and B-mode ultrasonography with pathology planes contributed significantly to the existence of mismatches. On the other hand, fixation and decalcification produced minimal and insignificant distortional changes. We conclude that the acquisition of quantitative data from endarterectomy specimens and the acceptance of morphologic data as a standard are limited by a number of problems that can be defined but have been difficult to resolve.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3