Carotid occlusive disease: effect of complete occlusion of internal carotid artery on intraocular pulse/pressure relation and on ophthalmic arterial pressure.

Author:

Langham M E,To'mey K F,Preziosi T J

Abstract

The intraocular pressure (IOP), the intraocular pulse to pressure (pulse/pressure) relationship, and the ophthalmic arterial pressure have been measured in 20 patients with either unilateral or bilateral hemodynamically significant lesions of the internal carotid arteries (ICA) as determined from arteriography. Studies were repeated in 5 of hte patients after surgical endarterectomy on the obstructed ICA. In age matched normal subjects the pulse/pressure relations were symmetrical in pairs of eyes, and the ophthalmic arterial systolic pressure was 89.0 +/- 2.1 mm Hg; this was 66 +/- 1% of the brachial arterial systolic pressure. In 19 of 20 patients with carotid occlusive disease in this study the IOP, pulse amplitudes and the pulse/pressure relationships differed in pairs of eyes. The ophthalmic arterial systolic pressure on the sides with 95 to 100% ICA stenosis was 49.9 +/- 4.05 mm Hg, which was 33 +/- 3% of the brachial arterial systolic pressure. In the remaining eyes the degree of stenosis of the ipsilateral ICA was 36.5 +/- 7.9%; the corresponding eyes had an ophthalmic arterial systolic pressure of 70.f1 +/- 51.18 mm Hg, which was 45 +/- 4% of the brachial arterial systolic pressure. Endarterectromy of the occluded arteries caused a significant increase in the ophthalmic arterial pressure on the ipsilateral side and a smaller increase in the contralateral eye; these changes were associated with a statistically significant increase in the intraocular pulse and improvement in the pulse/pressure relation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Reference21 articles.

1. A clinical procedure for the measurements of the ocular pulse-pressure relationship and the ophthalmic arterial pressure

2. The relationship between pressure and volume changes in living and dead rabbit eyes;Eisenlohr JE;Invest Ophthalmol,1962

3. MANOMETRIC STUDIES OF THE PRESSURE VOLUME RELATIONSHIP IN LIVING AND ENUCLEATED EYES OF INDIVIDUAL HUMAN SUBJECTS

4. Pneumatonography: A new methodological approach to the analysis of intraocular pressure and aqueous humor dynamics in human eyes. In Etienne R, Patterson GD (eds) International Glaucoma Symposium (Albi) 1974. Diffusion Generale de Librairic;Langham ME;Marseille,1975

5. Pneumatic applanation tonometer studies. III. Analysis of the floating tip sensor

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3