Abstract

Background: Current treatment of fluid retention in heart failure relies primarily on diuretics. However, adequate decongestion is not achieved in many patients. We aimed to study the feasibility and short-term performance of a novel approach to remove fluids and sodium directly from the interstitial compartment by enhancing sweat rate. Methods: We used a device designed to enhance fluid and salt loss via the eccrine sweat glands. Skin temperature in the lower body was increased from 35 °C to 38 °C, where the slope of the relationship between temperature and sweat production is linear. The sweat evaporates instantaneously, thus avoiding the awareness of perspiration. The primary efficacy endpoint was the ability to increase skin temperature to the desired range. A secondary efficacy endpoint was a clinically meaningful hourly sweat output, defined as ≥150 mL/h. The primary safety endpoint was any procedure-related adverse events. Results: We studied 6 normal subjects and 18 patients with congestion. Participants underwent 3 treatment sessions of up to 4 hours. Skin temperature increased to a median of 37.5 °C (interquartile range, 37.1–37.9 °C) with the median core temperature increasing by 0.2 °C (interquartile range, 0.1–0.3 °C). The median hourly weight loss during treatment was 215 g/h (interquartile range, 165–285; range, 100–344 g/h). In 80% of treatment procedures, the average sweat rate was ≥150 mL/h. There were no significant changes in hemodynamic variables or renal function and no procedure-related adverse events. Conclusions: Enhancing sweat rate was safe and resulted in a clinically meaningful fluid removal and weight loss. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04578353.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3