Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay

Author:

Varma Niraj1,O'Donnell David2,Bassiouny Mohammed1,Ritter Philippe3,Pappone Carlo4,Mangual Jan5,Cantillon Daniel1,Badie Nima5,Thibault Bernard6,Wisnoskey Brian5

Affiliation:

1. Cleveland Clinic, Cleveland, OH

2. Cardiology, Austin Health, Melbourne, Australia

3. University Hospital of Bordeaux, Pessac, France

4. Department of Electrophysiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy

5. Abbott, Sylmar, CA

6. Electrophysiology Service, Montreal Heart Institute, Montreal, Canada

Abstract

Background QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient‐specific conduction characteristics ( PR , qLV, LV ‐paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device‐based algorithm (Sync AV ) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Methods and Results Seventy‐five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128–300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration ( QRS d) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+Sync AV with 50 ms offset (Mode II ), BiV+Sync AV with offset that minimized QRS d (Mode III ), or LV ‐only pacing+Sync AV with 50 ms offset (Mode IV ). The intrinsic QRS d (162±16 ms) was reduced to 142±17 ms (−11.8%) by Mode I, 136±14 ms (−15.6%) by Mode IV , and 132±13 ms (−17.8%) by Mode II . Mode III yielded the shortest overall QRS d (123±12 ms, −23.9% [ P <0.001 versus all modes]) and was the only configuration without QRS d prolongation in any patient. QRS narrowing occurred regardless of QRS d, PR , or LV ‐paced intervals, or underlying ischemic disease. Conclusions Post‐implant electrical optimization in already well‐selected patients with left bundle branch block and optimized LV lead position is facilitated by patient‐tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device–based algorithm.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3