Volumetric Quantification of Global and Regional Left Ventricular Function From Real-Time Three-Dimensional Echocardiographic Images

Author:

Corsi Cristiana1,Lang Roberto M.1,Veronesi Federico1,Weinert Lynn1,Caiani Enrico G.1,MacEneaney Peter1,Lamberti Claudio1,Mor-Avi Victor1

Affiliation:

1. From the University of Chicago Medical Center, Chicago, Ill (C.C., R.M.L., L.W., P.M., V.M.-A); the Department of Electronics, Computer Science and Systems, University of Bologna, Bologna, Italy (C.C., F.V., C.L.); and the Dipartimento di Bioingegneria, Politecnico di Milano, Milan, Italy (E.G.C.).

Abstract

Background— Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. Methods and Results— RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)–time and wall motion (WM)–time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI ( r =0.98; y =0.99 x +2.3) with minimal bias (1.4 mL) and narrow limits of agreement (±20 mL). WM correlated highly only in basal and midventricular segments ( r =0.88; y =0.85 x +0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. Conclusions— Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 200 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3