Deformation of Transcatheter Aortic Valve Prostheses: Implications for Hypoattenuating Leaflet Thickening and Clinical Outcomes

Author:

Fukui Miho12ORCID,Bapat Vinayak N.32,Garcia Santiago32ORCID,Dworak Marshall W.32ORCID,Hashimoto Go12ORCID,Sato Hirotomo32ORCID,Gössl Mario32,Enriquez-Sarano Maurice2ORCID,Lesser John R.32,Cavalcante João L.12,Sorajja Paul32ORCID

Affiliation:

1. Cardiovascular Imaging Research Center and Core Laboratory (M.F., G.H., J.L.C.), Minneapolis Heart Institute Foundation, MN.

2. Minneapolis Heart Institute at Abbott Northwestern Hospital, MN (M.F., V.N.B., S.G., M.W.D., G.H., H.S., M.G., M.E.-S., J.R.L., J.L.C., P.S.).

3. Valve Science Center (V.N.B., S.G., M.W.D., H.S., M.G., M.E.-S., J.R.L., P.S.), Minneapolis Heart Institute Foundation, MN.

Abstract

Background: Although transcatheter aortic valve replacement (TAVR) therapy continues to grow, there have been concerns about the occurrence of hypoattenuating leaflet thickening (HALT), which may affect prosthesis function or durability. This study aimed to examine prosthesis frame factors and correlate their extent to the frequency of HALT and clinical outcomes. Methods: We prospectively examined 565 patients with cardiac computed tomography screening for HALT at 30 days after balloon-expandable SAPIEN3 and self-expanding EVOLUT TAVR. Deformation of the TAVR prostheses, asymmetric prosthesis leaflet expansion, prosthesis sinus volumes, and commissural alignment were analyzed on the postprocedural computed tomography. For descriptive purposes, an index of prosthesis deformation was calculated, with values >1.00 representing relative midsegment underexpansion. A time-to-event model was performed to evaluate the association of HALT with the clinical outcome. Results: Overall, HALT was present in 21% of SAPIEN3 patients and in 16% of EVOLUT patients at 30 days after TAVR. The occurrence of HALT was directly associated with greater prosthesis frame deformation ( P <0.001), worse asymmetry of the leaflets ( P <0.001), and smaller TAVR neosinus volumes ( P <0.001). These relations were present in both prosthetic types and in all of their size ranges (all P <0.05). In multivariable analyses that include clinical variables previously associated with HALT (eg, anticoagulant therapy), variables of TAVR prosthesis deformation remained predictive of HALT. Although HALT was not associated with changes in prosthetic hemodynamics, its presence was associated with the risk of mortality at 1 year, with respect to greater incidences of all-cause mortality (hazard ratio, 2.98 [95% CI, 1.57–5.63]; P =0.001), cardiac death (hazard ratio, 4.58 [95% CI, 1.81–11.6]; P =0.001), and a composite outcome of all-cause mortality and heart failure hospitalization (hazard ratio, 1.94 [95% CI, 1.14–3.30]; P =0.02) with adjustment for age, sex, and comorbidities. Conclusions: Nonuniform expansion of TAVR prostheses resulting in frame deformation, asymmetric leaflet, and smaller neosinus volume is related to occurrence of HALT in patients who undergo TAVR. These data may have implications for both prosthesis valve design and deployment techniques to improve clinical outcomes for these patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3