Incidence and Clinical Significance of Poststent Optical Coherence Tomography Findings

Author:

Soeda Tsunenari1,Uemura Shiro1,Park Seung-Jung1,Jang Yangsoo1,Lee Stephen1,Cho Jin-Man1,Kim Soo-Joong1,Vergallo Rocco1,Minami Yoshiyasu1,Ong Daniel S.1,Gao Lei1,Lee Hang1,Zhang Shaosong1,Yu Bo1,Saito Yoshihiko1,Jang Ik-Kyung1

Affiliation:

1. From Cardiology Division, Massachusetts General Hospital, Harvard Medical School, Boston, MA (T.S., R.V., Y.M., D.S.O., L.G., I.-K.J.); First Department of Medicine, Nara Medical University, Kashihara, Japan (T.S., S.U., Y.S.); Division of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea (S.-J.P.,); Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea (Y.J.); Queen Mary Hospital, Hong Kong University,...

Abstract

Background— Optical coherence tomography (OCT) was recently introduced to optimize percutaneous coronary intervention. However, the exact incidence and significance of poststent OCT findings are unknown. Methods and Results— A total of 900 lesions treated with 1001 stents in 786 patients who had postprocedure OCT imaging were analyzed to evaluate the incidence of poststent OCT findings and to identify the OCT predictors for device-oriented clinical end points, including cardiac death, target vessel–related myocardial infarction, target lesion revascularization, and stent thrombosis. Patients were followed up to 1 year. Stent edge dissection was detected in 28.7% of lesions, and incomplete stent apposition was detected in 39.1% of lesions. The incidences of smooth protrusion, disrupted fibrous tissue protrusion, and irregular protrusion were 92.9%, 61.0%, and 53.8%, respectively. Small minimal stent area, defined as a lesion with minimal stent area <5.0 mm 2 in a drug-eluting stent or <5.6 mm 2 in a bare metal stent, was observed in 40.4% of lesions. One-year device-oriented clinical end points occurred in 33 patients (4.5%). Following adjustment, irregular protrusion and small minimal stent area were independent OCT predictors of 1-year device-oriented clinical end points ( P =0.003 and P =0.012, respectively). Conclusions— Abnormal poststent OCT findings were frequent. Irregular protrusion and small minimal stent area were independent predictors of 1-year device-oriented clinical end points, which were primarily driven by target lesion revascularization.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3