Association Between Use of Primary-Prevention Implantable Cardioverter-Defibrillators and Mortality in Patients With Heart Failure

Author:

Schrage Benedikt12,Uijl Alicia13,Benson Lina1,Westermann Dirk2,Ståhlberg Marcus1,Stolfo Davide14,Dahlström Ulf5,Linde Cecilia1,Braunschweig Frieder1,Savarese Gianluigi1

Affiliation:

1. Division of Cardiology, Department of Medicine, Karolinska Institutet, Stockholm, Sweden (B.S., A.U., L.B., M.S., D.S., C.L., F.B., G.S.).

2. University Heart Centre Hamburg, Department of General and Interventional Cardiology and German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel (B.S., D.W.).

3. Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, The Netherlands (A.U.).

4. Division of Cardiology, Cardiovascular Department, Azienda Sanitaria Universitaria Integrata di Trieste, Italy (D.S.).

5. Department of Cardiology and Department of Medical and Health Sciences, Linköping University, Sweden (U.D.).

Abstract

Background: Most randomized trials on implantable cardioverter-defibrillator (ICD) use for primary prevention of sudden cardiac death in heart failure with reduced ejection fraction enrolled patients >20 years ago. We investigated the association between ICD use and all-cause mortality in a contemporary heart failure with reduced ejection fraction cohort and examined relevant subgroups. Methods: Patients from the Swedish Heart Failure Registry fulfilling the European Society of Cardiology criteria for primary-prevention ICD were included. The association between ICD use and 1-year and 5-year all-cause and cardiovascular (CV) mortality was assessed by Cox regression models in a 1:1 propensity score–matched cohort and in prespecified subgroups. Results: Of 16 702 eligible patients, only 1599 (10%) had an ICD. After matching, 1305 ICD recipients were compared with 1305 nonrecipients. ICD use was associated with a reduction in all-cause mortality risk within 1 year (hazard ratio, 0.73 [95% CI, 0.60–0.90]) and 5 years (hazard ratio, 0.88 [95% CI, 0.78–0.99]). Results were consistent in all subgroups including patients with versus without ischemic heart disease, men versus women, those aged <75 versus ≥75 years, those with earlier versus later enrollment in the Swedish heart failure registry, and patients with versus without cardiac resynchronization therapy. Conclusions: In a contemporary heart failure with reduced ejection fraction population, ICD for primary prevention was underused, although it was associated with reduced short- and long-term all-cause mortality. This association was consistent across all the investigated subgroups. These results call for better implementation of ICD therapy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3