Affiliation:
1. From the Departments of Medicine (K.C.B., S.K., J.P.D.) and Public Health Sciences (G.J.S.), University of Virginia Health System, Charlottesville.
Abstract
Background—
Clinical trials of cardiac resynchronization therapy (CRT) have enrolled a select group of patients, with few patients in subgroups such as right bundle-branch block (RBBB). Analysis of population-based outcomes provides a method to identify real-world predictors of CRT outcomes.
Methods and Results—
Medicare Implantable Cardioverter-Defibrillator Registry (2005 to 2006) data were merged with patient outcomes data. Cox proportional-hazards models assessed death and death/heart failure hospitalization outcomes in patients with CRT and an implantable cardioverter-defibrillator (CRT-D). The 14 946 registry patients with CRT-D (median follow-up, 40 months) had 1-year, 3-year, and overall mortality rates of 12%, 32%, and 37%, respectively. New York Heart Association class IV heart failure status (1-year hazard ratio [HR], 2.23; 3-year HR, 1.98;
P
<0.001) and age ≥80 years (1-year HR, 1.74; 3-year HR, 1.75;
P
<0.001) were associated with increased mortality both early and late after CRT-D. RBBB (1-year HR, 1.44; 3-year HR, 1.37;
P
<0.001) and ischemic cardiomyopathy (1-year HR, 1.39; 3-year HR, 1.44;
P
<0.001) were the next strongest adjusted predictors of both early and late mortality. RBBB and ischemic cardiomyopathy together had twice the adjusted hazard for death (HR, 1.99;
P
<0.001) as left BBB and nonischemic cardiomyopathy. QRS duration of at least 150 ms predicted more favorable outcomes in left BBB but had no impact in RBBB. A secondary analysis showed lower hazards for CRT-D compared with standard implantable cardioverter-defibrillators in left BBB compared with RBBB.
Conclusions—
In Medicare patients, RBBB, ischemic cardiomyopathy, New York Heart Association class IV status, and advanced age were powerful adjusted predictors of poor outcome after CRT-D. Real-world mortality rates 3 to 4 years after CRT-D appear higher than previously recognized.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Cited by
215 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献