Mechanisms of Ventricular Fibrillation in Canine Models of Congestive Heart Failure and Ischemia Assessed by In Vivo Noncontact Mapping

Author:

Everett Thomas H.1,Wilson Emily E.1,Foreman Scott1,Olgin Jeffrey E.1

Affiliation:

1. From the Division of Cardiology and the Cardiovascular Research Institute, University of California San Francisco, San Francisco.

Abstract

Background— Much of the research performed studying the mechanism of ventricular fibrillation (VF) has been in normal ventricles rather than under a pathological condition predisposing to VF. We hypothesized that different ventricular substrates would alter the mechanism and characteristics of VF. Methods and Results— Three groups of dogs were studied: (1) control (n=8), (2) pacing-induced congestive heart failure (n=7), and (3) acute ischemia produced by 30 minutes of mid left anterior descending artery ligation (n=5). A noncontact mapping catheter (Ensite 3000, ESI) was placed via transseptal into the left ventricle (LV), along with an electrophysiology catheter. A multielectrode basket catheter (EP Technologies) was placed in the right ventricle, along with an electrophysiology catheter. Several episodes of VF were recorded in each animal. In addition to constructing isopotential and isochronal maps of the VF episodes, signals underwent frequency domain analysis as a fast Fourier transform was performed over a 2-second window every 1 second. From the fast Fourier transform, the dominant frequency was determined, and the organization was calculated. In control dogs, meandering, reentrant spiral wave activity was the main feature of the VF. The congestive heart failure group showed evidence of a stable rotor (n=3), evidence of a focal source (n=3), or no evidence of a driver in the LV (n=1). The ischemic group showed evidence of an initial focal mechanism that transitioned into reentry. In the control and ischemic groups, the LV always had higher dominant frequencies than the right ventricle. Conclusions— Different ventricular substrates produced by the different animal models altered the characteristics of VF. Thus, different mechanisms of VF may be present in the LV, depending on the animal model.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 31 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3