Long-Term Outcome of Aortic Dissection With Patent False Lumen

Author:

Evangelista Artur1,Salas Armando1,Ribera Aida1,Ferreira-González Ignacio1,Cuellar Hug1,Pineda Victor1,González-Alujas Teresa1,Bijnens Bart1,Permanyer-Miralda Gaietà1,Garcia-Dorado David1

Affiliation:

1. From the Servei de Cardiologia (A.E., A.S., A.R., I.F.-G., T.G.-A., B.B., G.P.-M., D.G.-D.), Institut de Diagnòstic per la Imatge (H.C., V.P.), Hospital Vall d'Hebron, Universitat Autonoma de Barcelona; Unitat de Epidemiologia, CIBER de Epidemiología y Salud Pública (CIBERESP) (A.R., I.F.-G., G.P.-M.); and Institució Catalana de Recerca i Estudis Avançats (B.B.), Barcelona, Spain.

Abstract

Background— Patent false lumen in aortic dissection has been associated with poor prognosis. We aimed to assess the natural evolution of this condition and predictive factors. Methods and Results— One hundred eighty-four consecutive patients, 108 surgically treated type A and 76 medically treated type B, were discharged after an acute aortic dissection with patent false lumen. Transesophageal echocardiography was performed before discharge, and computed tomography was performed at 3 months and yearly thereafter. Median follow-up was 6.42 years (quartile 1 to quartile 3: 3.31–10.49). Forty-nine patients died during follow-up (22 type A, 27 type B), 31 suddenly. Surgical or endovascular treatment was indicated in 10 type A and 25 type B cases. Survival free from sudden death and surgical-endovascular treatment was 0.90, 0.81, and 0.46 (95% CI, 0.36–0.55) at 3, 5, and 10 years, respectively. Multivariate analysis identified baseline maximum descending aorta diameter (hazard ratio [HR]: 1.32 [1.10–1.59]; P =0.003), proximal location (HR: 1.84 [1.06–3.19]; P =0.03), and entry tear size (HR: 1.13 [1.08–1.2]; P <0.001) as predictors of dissection-related adverse events, whereas mortality was predicted by baseline maximum descending aorta diameter (HR: 1.36 [1.08–1.70]; P =0.008), entry tear size (HR: 1.1 [1.04–1.16]; P =0.001), and Marfan syndrome (HR: 3.66 [1.65–8.13]; P =0.001). Conclusions— Aortic dissection with persistent patent false lumen carries a high risk of complications. In addition to Marfan syndrome and aorta diameter, a large entry tear located in the proximal part of the dissection identifies a high-risk subgroup of patients who may benefit from earlier and more aggressive therapy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3