Risk of Rupture or Dissection in Descending Thoracic Aortic Aneurysm

Author:

Kim Joon Bum1,Kim Kibeom1,Lindsay Mark E.1,MacGillivray Thomas1,Isselbacher Eric M.1,Cambria Richard P.1,Sundt Thoralf M.1

Affiliation:

1. From Division of Cardiac Surgery (J.B.K., T.M., T.M.S.), Thoracic Aortic Center (J.B.K., K.K., T.M., E.M.I., R.P.C., T.M.S.), Cardiology Division (M.E.L., E.M.I.), Pediatric Cardiology (M.E.L.), and Vascular and Endovascular Surgery (R.P.C.), Massachusetts General Hospital, Harvard Medical School, Boston; and Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea (J.B.K., M.E.L.).

Abstract

Background— Current practice guidelines recommend surgical repair of large thoracic aortic aneurysms to prevent fatal aortic dissection or rupture, but limited natural history data exist to support clinical criteria for timely intervention. Methods and Results— Of 3247 patients with thoracic aortic aneurysm registered in our institutional Thoracic Aortic Center Database, we identified and reviewed 257 nonsyndromic patients (age, 72.4±10.5 years; 143 female) with descending thoracic or thoracoabdominal aortic aneurysm without a history of aortic dissection in whom surgical intervention was not undertaken. The primary end point was a composite of aortic dissection/rupture and sudden death. Baseline mean maximal aortic diameter was 52.4±10.8 mm, with 103 patients having diameters ≥55 mm. During a median follow-up of 25.1 months (quartiles 1–3, 8.3–56.4 months), definite and possible aortic events occurred in 19 (7.4%) and 31 (12.1%) patients, respectively. On multivariable analyses, maximal aortic diameter at baseline emerged as the only significant predictor of aortic events (hazard ratio=1.12; 95% confidence interval, 1.08–1.15). Estimated rates of definite aortic events within 1 year were 5.5%, 7.2%, and 9.3% for aortic diameters of 50, 55, and 60 mm, respectively. Receiver-operating characteristic curves for discriminating aortic events were higher for indexed aortic sizes referenced by body size (area under the curve=0.832–0.889) but not significantly different from absolute maximal aortic diameter (area under the curve=0.805). Conclusions— Aortic size was the principal factor related to aortic events in unrepaired descending thoracic or thoracoabdominal aortic aneurysm. Although the risk of aortic events started to increase with a diameter >5.0 to 5.5 cm, it is uncertain whether repair of thoracic aortic aneurysms in this range leads to overall benefit, and the threshold for repair requires further evaluation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 82 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3