Mechanisms Underlying the Lack of Effect of Implantable Cardioverter-Defibrillator Therapy on Mortality in High-Risk Patients With Recent Myocardial Infarction

Author:

Dorian Paul1,Hohnloser Stefan H.1,Thorpe Kevin E.1,Roberts Robin S.1,Kuck Karl-Heinz1,Gent Michael1,Connolly Stuart J.1

Affiliation:

1. From the Keenan Research Center, Li Ka Shing Institute, St Michael's Hospital, and the University of Toronto, Toronto, Ontario, Canada (P.D.); Goethe University Hospital, Frankfurt, Germany (S.H.H.); Dalla Lana School of Public Health, University of Toronto, and Applied Health Research Centre, St Michael's Hospital, Toronto, Ontario, Canada (K.E.T.); McMaster University, Hamilton, Ontario, Canada (R.S.R., M.G.); Asklepios Hospital, St Georg, Hamburg, Germany (K.-H.K.); and Population Health Research...

Abstract

Background— Although implantable cardioverter-defibrillators (ICDs) lower mortality in stable patients with low ejection fraction late after myocardial infarction, randomized trials of ICD versus control subjects implanted early after myocardial infarction do not show mortality benefit. Our objective was to investigate possible mechanisms underlying the lack of mortality benefit in the Defibrillation in Acute Myocardial Infarction Trial (DINAMIT). Methods and Results— This is a secondary analysis of the prospective randomized clinical trial. Outpatients with recent (6 to 40 days) acute myocardial infarction, left ventricular dysfunction (ejection fraction <35%), and low heart rate variability were randomized to ICD (n=311) or to standard medical therapy (n=342). In a competing-risks analysis, those factors that increased the risk of arrhythmic death also increased the risk of nonarrhythmic deaths. After adjustment for these factors, receiving an ICD was associated with a decreased risk of arrhythmic death (hazard ratio, 0.33; 95% confidence interval, 0.15 to 0.71) but an increase in nonarrhythmic death (hazard ratio, 1.70; 95% confidence interval, 1.00 to 2.80). In an adjusted time-dependent analysis, patients receiving an ICD and having appropriate ICD therapy had a 15.1% yearly hazard of mortality compared with 5.2% in ICD patients with no appropriate therapy ( P <0.001). The reduction in sudden death in ICD patients was completely offset by increased nonarrhythmic deaths, which were greatest in patients receiving ICD shock therapy (hazard ratio, 6.0; 95% confidence interval, 2.8 to 12.7). Conclusions— In patients receiving ICDs early after myocardial infarction, those factors that are associated with arrhythmia requiring ICD therapy are also associated with a high risk of nonsudden death, negating the benefit of ICDs in this setting.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3