Outcomes of Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Disease

Author:

Halim Sharif A.12,Edwards Fred H.3,Dai David1,Li Zhuokai1,Mack Michael J.4,Holmes David R.5,Tuzcu E. Murat6,Thourani Vinod H.7,Harrison J. Kevin1,Brennan J. Matthew8ORCID

Affiliation:

1. Duke Clinical Research Institute (S.A.H., D.D., Z.L., J.K.H.), Duke University Medical Center, Durham, NC.

2. Presbyterian Heart Center, Albuquerque, NM (S.A.H.).

3. University of Florida Health Science Center, Jacksonville (F.H.E.).

4. Heart Hospital Baylor Plano Research Center, TX (M.J.M.).

5. Mayo Clinic, Rochester, MN (D.R.H.).

6. Cleveland Clinic, OH (E.M.T.).

7. Emory University School of Medicine, Atlanta, GA (V.H.T.).

8. Duke University School of Medicine (J.M.B.), Duke University Medical Center, Durham, NC.

Abstract

Background: Patients with bicuspid aortic valve (AV) stenosis were excluded from the pivotal evaluations of transcatheter AV replacement (TAVR) devices. We sought to evaluate the outcomes of TAVR in patients with bicuspid AV stenosis in comparison with those with tricuspid AV stenosis. Methods: We used data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry (November 2011 through November 2018) to determine device success, procedural outcomes, post-TAVR valve performance, and in-hospital clinical outcomes (mortality, stroke, and major bleeding) according to valve morphology (bicuspid versus tricuspid). Results were stratified by older and current (Sapien 3 and Evolut R) generation valve prostheses. Medicare administrative claims were used to evaluate mortality and stroke to 1 year among eligible individuals (≥65 years). Results: After exclusions, there were 170 959 eligible procedures at 593 sites during the specified interval. Of these, 5412 TAVR procedures (3.2%) were performed in patients with bicuspid AV, including 3705 with current-generation devices. In comparison with patients with tricuspid valves, patients with bicuspid AV were younger and had a lower Society of Thoracic Surgeons Predicted Risk of Operative Mortality score. When current-generation devices were used to treat patients with bicuspid AV, device success increased (93.5 versus 96.3; P =0.001) and the incidence of 2+ aortic insufficiency declined (14.0% versus 2.7%; P <0.001) in comparison with older-generation devices. With current-generation devices, device success was slightly lower in the bicuspid (versus tricuspid) AV group (96.3% in bicuspid versus 97.4% in tricuspid, P =0.07), with a slightly higher incidence of residual moderate or severe aortic insufficiency among patients with bicuspid AV (2.7% versus 2.1%; P <0.001). A lower 1-year adjusted risk of mortality (hazard ratio, 0.88 [95% CI, 0.78–0.99]) was observed for patients with bicuspid AV versus patients with tricuspid AV in the Medicare-linked cohort, whereas no difference was observed in the 1-year adjusted risk of stroke (hazard ratio, 1.14 [95% CI, 0.94–1.39]). Conclusions: Using current-generation devices, procedural, postprocedural, and 1-year outcomes were comparable following TAVR for bicuspid AV versus tricuspid AV disease. With newer-generation devices, TAVR is a viable treatment option for patients with bicuspid AV disease.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3