Pioglitazone Reduces Neointima Volume After Coronary Stent Implantation

Author:

Marx Nikolaus1,Wöhrle Jochen1,Nusser Thorsten1,Walcher Daniel1,Rinker Angelika1,Hombach Vinzenz1,Koenig Wolfgang1,Höher Martin1

Affiliation:

1. From the Department of Internal Medicine II, Cardiology, University of Ulm, Ulm, Germany.

Abstract

Background— Restenosis requiring reintervention limits the long-term success after coronary stent implantation. Thiazolidinediones, like pioglitazone or rosiglitazone, are oral antidiabetic drugs with additional antirestenotic properties. In a randomized, placebo-controlled, double-blind trial, we examined the effect of 6-month pioglitazone therapy on neointima volume after coronary stenting in nondiabetic coronary artery disease patients. Methods and Results— Fifty nondiabetic patients after coronary stent implantation were randomly assigned to pioglitazone (30 mg daily; pio) or placebo (control) treatment in addition to standard therapy, and neointima volume was assessed by intravascular ultrasound at the 6-month follow-up. Both groups were comparable with regard to baseline characteristics, angiographic lesion morphology, target vessel, and length of the stented segment. In addition, there were no statistical differences in minimal lumen diameter before and after intervention, as well as reference diameter after stent implantation. In this study population of nondiabetic patients, pio treatment did not significantly change fasting blood glucose, fasting insulin, or glycosylated hemoglobin levels, as well as lipid parameters. In contrast, pio treatment significantly reduced neointima volume within the stented segment, with 2.3±1.1 mm 3 /mm in the pio group versus 3.1±1.6 mm 3 /mm in controls ( P =0.04). Total plaque volume (adventitia-lumen area) was significantly lower at follow-up in the pio group (11.2±3.2 mm 3 /mm) compared with controls (13.2±4.2 mm 3 /mm; P =0.04). Moreover, the binary restenosis rate was 3.4% in the pio group versus 32.3% in controls ( P <0.01). Conclusions— Thus, 6-month treatment with pio significantly reduced neointima volume after coronary stent implantation in nondiabetic patients. These data bolster the hypothesis that antidiabetic thiazolidinediones, in addition to their metabolic effects, exhibit direct antirestenotic effects in the vasculature.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 155 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3