Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up

Author:

Varma Niraj1,Epstein Andrew E.1,Irimpen Anand1,Schweikert Robert1,Love Charles1

Affiliation:

1. From the Cleveland Clinic, Cleveland, Ohio (N.V.); University of Pennsylvania, Philadelphia (A.E.); Tulane University Medical Center, New Orleans, La (A.I.); Akron General Medical Center, Akron, Ohio (R.S.); and Davis Heart and Lung Research Institute, Ohio State University, Columbus (C.L.).

Abstract

Background— Monitoring implantable cardiac device function and patient condition is important. The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial tested the hypothesis that remote home monitoring with automatic daily surveillance (HM) is safe and effective for implantable cardioverter-defibrillator follow-up for 1 year and enables rapid physician evaluation of significant events. Methods and Results— In total, 1339 patients were randomized 2:1 to HM or conventional follow-up. Follow-up checks occurred at 3, 6, 9, 12, and 15 months after implantation. HM was used before office visits at 3 and 15 months in the HM group. At 6, 9, and 12 months, HM only was used but was followed by office visits if necessary. Conventional patients were evaluated with office visits only. Scheduled office visits and unscheduled evaluations, incidence of morbidity, and time elapsed from first event occurrence in each patient to physician evaluation were tracked for each group. HM and conventional patients were similar (age, 63.3±12.8 versus 64.0±12.1 years; gender, 72.0% versus 73.1% male; New York Heart Association class II, 55.9% versus 60.4%; pathology: left ventricular ejection fraction, 29.0±10.7% versus 28.5±9.8%; coronary artery disease, 64.8% versus 71.7%; primary prevention indication, 72.2% versus 73.8%; and dual-chamber implants, 57.8% versus 56.6%). HM reduced total in-hospital device evaluations by 45% without affecting morbidity. In the HM group, 85.8% of all 6-, 9-, and 12-month follow-ups were performed remotely only, indicating that HM provided sufficient assessment in the majority. Median time to evaluation was <2 days in the HM group compared with 36 days in the conventional group ( P <0.001) for all arrhythmic events. Conclusions— HM is safe and allows more rapid detection of actionable events compared with conventional monitoring in patients with implantable electronic cardiac devices. Clinical Trials Registration—URL: http:/www.clinicaltrials.gov. Unique identifier: NCT00336284.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3